Mostrar el registro sencillo del ítem

dc.contributor.authorVílchez Membrilla, José Antonio 
dc.contributor.authorSalas Moreno, Víctor 
dc.contributor.authorKoponen, Maria A
dc.contributor.authorSouza, V.H.
dc.contributor.authorPantoja, M.F.
dc.contributor.authorIlmoniemi, Risto J
dc.contributor.authorCobos Sánchez, Clemente 
dc.contributor.otherIngeniería en Automática, Electrónica, Arquitectura y Redes de Computadoreses_ES
dc.date.accessioned2026-11-23T09:12:26Z
dc.date.available2026-11-23T09:12:26Z
dc.date.issued2026
dc.identifier.issn2469-7249
dc.identifier.urihttp://hdl.handle.net/10498/40805
dc.description.abstractObjective: Interleaving transcranial magnetic stimulation with magnetic resonance imaging (TMS-MRI) is a promising tool for neuroscience. However, its development is limited by the strong interactions between the TMS current pulse and the high magnetic field present within the MRI environment. The objective of this study is to develop methodologies for designing TMS coils that can operate safely inside MRI scanners. Methods: By using an inverse boundary element method design framework, we study the effects of controlling different norms of the Lorentz force in the design process to produce more durable TMS coils. We apply this method to design rodent-specific TMS coils capable of withstanding the high static magnetic fields present in small animal MRI scanners. The performance of the proposed TMS coils is validated under realistic simulations using practical coil plate materials and pulses in the COMSOL Multiphysics software. Results: The numerical simulations indicate that minimising the maximum magnitude ($l<^>{\infty}$ norm) of the Lorentz force distribution produces TMS coils with improved mechanical behaviour when operating within an MRI environment. Significance: The proposed design strategy offers an effective solution for producing TMS coils with enhanced mechanical durability. This improvement may be particularly valuable to address the current challenges faced in interleaved TMS-MRI applications.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INCes_ES
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/es_ES
dc.sourceIEEE Journal of Electromagnetics, RF and Microwaves in Medicine and Biology, Vol. 10, Núm. 1, 2026, pp. 170-178es_ES
dc.subjectCoilses_ES
dc.subjectMagnetic resonance imaginges_ES
dc.subjectStresses_ES
dc.subjectLorentz covariancees_ES
dc.subjectElectric fieldses_ES
dc.subjectMagnetic fieldses_ES
dc.subjectOptimizationes_ES
dc.subjectBrain modelinges_ES
dc.subjectElectromagneticses_ES
dc.subjectPerformance metricses_ES
dc.subjectTMSes_ES
dc.subjectMRIes_ES
dc.subjectIBEMes_ES
dc.subjectCoil Designes_ES
dc.subjectCOMSOL Simulationes_ES
dc.titleDesign of Mechanical Durable TMS Coils for Safe Operation in High-Field MRI Environmentses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1109/JERM.2025.3649258
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/810377/EU es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/Junta de Andalucía//ProyExcel01036es_ES
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

http://creativecommons.org/licenses/by/4.0/
Esta obra está bajo una Licencia Creative Commons http://creativecommons.org/licenses/by/4.0/