Show simple item record

dc.contributor.authorGarcía Guzmán, Juan José 
dc.contributor.authorLópez-Iglesias, David
dc.contributor.authorCubillana Aguilera, Laura 
dc.contributor.authorLete, Cecilia
dc.contributor.authorLupu, Stelian
dc.contributor.authorPalacios Santander, José María 
dc.contributor.authorBellido Milla, Dolores 
dc.contributor.otherQuímica Analíticaen_US
dc.date.accessioned2019-06-04T07:07:14Z
dc.date.available2019-06-04T07:07:14Z
dc.date.issued2019-01
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10498/21340
dc.description.abstractThe application of a novel Poly(3,4-ethylenedioxythiophene)-Tyrosinase/Sonogel-Carbon electrode (PEDOT-Tyr/SNGC) biosensor to beers and wines analysis is proposed. This biosensor implies a new Sinusoidal Current (SC) electrodeposition method to immobilize the enzyme generating a nanostructure surface. The biosensors were characterized electrochemically, employing cyclic voltammetry and electrochemical impedance spectroscopy. Sensitivity, limit of detection, and correlation coefficients of the linear fitting were 2.40 104 A M1, 4.33 M, and R2 = 0.9987, respectively. Caffeic acid is used as the reference polyphenol. A sampling of nine beers (four lager, three stout, and two non-alcoholic beers), and four wines (three red and one white wine) purchased in a local store was performed. The Polyphenol indeces for beers and wines have been assessed using the proposed biosensor, and the obtained values are in agreement with the literature data. Antioxidant properties of the samples using the 2,20-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid (ABTS) radical spectrophotometric method were also evaluated. The correlation between the polyphenol index and the antioxidant capacity was obtained for beers and wines.en_US
dc.formatapplication/pdfen_US
dc.language.isoengen_US
dc.publisherMDPIen_US
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceSensors 2019, 19 (1) art. 66en_US
dc.subjectsonogel–carbon based biosensoren_US
dc.subjectsinusoidal current methoden_US
dc.subjectpolyphenol indexen_US
dc.subjectantioxidant capacityen_US
dc.subjectbeer and wineen_US
dc.titleAssessment of the Polyphenol Indices and Antioxidant Capacity for Beers and Wines Using a Tyrosinase-Based Biosensor Prepared by Sinusoidal Current Methoden_US
dc.typejournal articleen_US
dc.rights.accessRightsopen accessen_US
dc.identifier.doi10.3390/s19010066


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional