Show simple item record

dc.contributor.authorPuyana Romero, Virginia 
dc.contributor.authorNúñez-Solano, Daniel
dc.contributor.authorHernández Molina, Ricardo 
dc.contributor.authorJara-Muñoz, Edgar
dc.contributor.otherMáquinas y Motores Térmicoses_ES
dc.date.accessioned2020-11-16T13:30:42Z
dc.date.available2020-11-16T13:30:42Z
dc.date.issued2020-09
dc.identifier.issn2296-2360
dc.identifier.urihttp://hdl.handle.net/10498/23938
dc.description.abstractThe neonatal intensive care unit (NICU) is a very noisy place as compared to the intrauterine environment. To protect the neonate's health, international guidelines suggest avoiding noise levels above 45 dB in NICUs, but this recommendation is not normally met. The incubator acoustic isolation and the acoustic features of the NICU play important roles in determining the noise measured inside the incubator. In this study, the influence of two types of rooms, one with sound-absorbent covering and the other with reverberant surfaces, on the acoustic isolation of a neonatal incubator was evaluated using three acoustic isolation indexes: the level difference, the apparent sound reduction index, and the standardized level difference. Results show that the acoustic isolation of the incubator is very poor, with a level difference below 11 dBA at all frequencies. At 62.5 Hz, the level difference measured in both rooms exhibits a negative value, indicating that the incubator amplifies the noise coming from the NICU. Isolation of the incubator is poor, and the reverberation time (RT) of the containing room influences RT of the incubator, which is consequently higher when the containing room is reverberant; for example, the incubator RT in the reverberant NICU is 0.72 s higher at 500 Hz than that in a room with sound-absorbent covering.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherFRONTIERS MEDIA SAes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceFront. Pediatr. 8:588.es_ES
dc.subjectacoustic environmentes_ES
dc.subjectlow frequency noisees_ES
dc.subjectacoustic isolationes_ES
dc.subjectneonatal incubatores_ES
dc.subjectreverberation timees_ES
dc.titleInfluence of the NICU on the Acoustic Isolation of a Neonatal Incubatores_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3389/fped.2020.00588


Files in this item

This item appears in the following Collection(s)

Show simple item record

Atribución 4.0 Internacional
This work is under a Creative Commons License Atribución 4.0 Internacional