Mostrar el registro sencillo del ítem

dc.contributor.authorSánchez Morillo, Daniel 
dc.contributor.authorLara Doña, Alejandro 
dc.contributor.authorPriego Torres, Blanca María 
dc.contributor.authorMorales Gonzalez, Maria
dc.contributor.authorMontoro Ballesteros, Francisca 
dc.contributor.authorLeón Jiménez, Antonio
dc.contributor.otherIngeniería en Automática, Electrónica, Arquitectura y Redes de Computadoreses_ES
dc.date.accessioned2021-01-29T11:03:33Z
dc.date.available2021-01-29T11:03:33Z
dc.date.issued2020-12
dc.identifier.issn2077-0383
dc.identifier.urihttp://hdl.handle.net/10498/24355
dc.description.abstractThe appropriate titration for the personalized oxygen needs of patients with chronic obstructive pulmonary disease (COPD) and severe hypoxemia is a determining factor in the success of long-term oxygen therapy. There are no standardized procedures to assist in determining the patient's needs during the physical activities of daily life. Despite that effort tests are a wide broad approach, further research concerning the development of protocols to titrate O-2 therapy is needed. The main objective of this study was to assess whether the level of oxygen titrated through the 6-minute walking test (6MWT) for patients with COPD and exertional hypoxemia is adequate to meet the patients' demand during their activities of daily living. Physiological and subjective variables were estimated for a study population during two walking tests: a 6MWT and a 20-minute walking circuit (20MWC), designed ad-hoc to reproduce daily physical activities more truthfully. The results indicate that in a significant proportion of patients, the 6MWT might not accurately predict their oxygen needs at a domiciliary environment. Therefore, the titration of the portable O-2 therapy could not be optimal in these cases, with the detrimental impact on the patient's health (hyperoxia episodes), the autonomy of the oxygen device, and the decrease of time out of the home.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publishermes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceJ. Clin. Med. 2020, 9(12), 4007es_ES
dc.subjectCOPDes_ES
dc.subjectoxygen therapyes_ES
dc.subject6-minute walk testes_ES
dc.subjectCT90es_ES
dc.subjectoximetryes_ES
dc.subjectoxygen therapyes_ES
dc.titlePortable Oxygen Therapy: Is the 6-Minute Walking Test Overestimating the Actual Oxygen Needs?es_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/jcm9124007


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Atribución 4.0 Internacional