Show simple item record

dc.contributor.authorSuffo Pino, Miguel 
dc.contributor.authorRevenga, Carlos
dc.contributor.otherIngeniería Mecánica y Diseño Industriales_ES
dc.date.accessioned2022-01-19T13:02:41Z
dc.date.available2022-01-19T13:02:41Z
dc.date.issued2021-10
dc.identifier.issn1996-1944
dc.identifier.urihttp://hdl.handle.net/10498/26019
dc.description.abstractThe increase in the number of revision surgeries after a total knee replacement surgery reaches 19%. One of the reasons for the majority of revisions relates to the debris of the ultra-high molecular weight polyethylene that serves to facilitate the sliding between the femoral and tibial components. This paper addresses the biomechanical properties of ULTEMTM 1010 in a totally new knee replacement design, based on one of the commercial models of the Stryker manufacturer. It is designed and produced through additive manufacturing that replaces the tibial component and the polyethylene in such a way as to reduce the pieces that are part of the prosthetic assembly to only two: the femoral and the tibial (the so-called “two-component knee prosthesis”). The cytotoxicity as well as the live/dead tests carried out on a series of biomaterials guarantee the best osteointegration of the studied material. The finite element simulation method guarantees the stability of the material before a load of 2000 N is applied in the bending angles 0 , 30 , 60 , 90 , and 120 . Thus, the non-metallic prosthetic material and approach represent a promising alternative for metal-allergic patients.es_ES
dc.description.sponsorshipThe live/dead test was exclusively supported by the Andalucia FEDER/ITI 2014-2020 Grant for PI 013/017, as well as the Junta de Andalucia TEP 181 and the CTS 253 PAIDI Spanish research groups.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceMaterials 2021, 14(20), 5951es_ES
dc.subjectnon-metallic knee prosthesises_ES
dc.subjectULTEMTM 1010 biomateriales_ES
dc.subjectadditive manufacturinges_ES
dc.subjectbiomechanical designes_ES
dc.subjecttwo-component knee prosthesises_ES
dc.subjectlive/deades_ES
dc.titleBiomechanical Analysis of Non-Metallic Biomaterial in the Manufacture of a New Knee Prosthesises_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/ma14205951
dc.relation.projectIDinfo:eu-repo/grantAgreement/Junta de Andalucía//PI0013-2017es_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Atribución 4.0 Internacional
This work is under a Creative Commons License Atribución 4.0 Internacional