• español
    • English
  • Login
  • English 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Communities and Collections
View Item 
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Fresnel solar cooling plant for buildings: Optimal operation of an absorption chiller through inverse modelling

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/26373

DOI: 10.1016/j.egyr.2022.02.128

ISSN: 2352-4847

Files
APC_2022_018.pdf (3.756Mb)
Statistics
View statistics
Metrics and citations
 
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
Guerrero Delgado, MCarmen; Sánchez Ramos, José; Castro Medina, DanielAuthority UCA; Palomo Amores, Teresa Rocío; Cerezo Narváez, AlbertoAuthority UCA; Álvarez Domínguez, Servando
Date
2022
Department
Ingeniería Mecánica y Diseño Industrial
Source
Energy Reports 8 (2022) 3189–3212
Abstract
Increasing comfort conditions in buildings imply higher energy demands. However, these needs can be mitigated by solar cooling solutions. These systems, such as absorption chillers, are complex and require stable operation, with strict control to maximise the solar fraction and minimise gas consumption. This is incompatible with the variability of renewable resources, so they are often coupled with auxiliary gas systems. Although gas-free operation is possible if these systems are optimally controlled, they would require special supervision. This paper aims to develop an experimental validation of an inverse model to manage an absorption chiller coupled with a solar cooling plant. To know its real behaviour, long-term experiments have been performed using this plant, which consists of a linear Fresnel solar collector and an auxiliary natural gas boiler. The inverse model is used as a predictive control tool to decide the auxiliary boiler commands of the absorption chiller to optimise its operation: maximum cooling production by minimising gas consumption and maximising solar contribution. It has been identified with data from two weeks and validated with data from one summer month. Results show that the model estimates, on a time base of fewer than 30 min, are acceptable with errors of less than 5%. In addition, the maximum error of the estimated seasonal COP and the renewable fraction are less than 6% per day. Therefore, the results prove the usefulness of the proposal as a predictive control for optimal operation. Furthermore, it could be used as a baseline for preventive maintenance. If the proposed model is used for optimal management of the absorption chiller, the thermal efficiency of the plant increases significantly, doubling the solar contribution. As a result, the gas consumption of the solar cooling plant is halved and the total cost of air conditioning the building decreases by 16%. © 2022 The Authors
Subjects
Solar cooling plant; Absorption chiller; Double effect; Inverse modelling; Renewable energy integration
Collections
  • Artículos Científicos [11973]
  • Articulos Científicos Ing. Mec. [325]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support