Mostrar el registro sencillo del ítem

dc.contributor.authorSánchez Ponce, Lorena
dc.contributor.authorGalindo Riaño, María Dolores 
dc.contributor.authorCasanueva Marenco, María José 
dc.contributor.authorGranado Castro, María Dolores 
dc.contributor.authorDíaz de Alba, Margarita Isabel 
dc.contributor.otherQuímica Analíticaes_ES
dc.date.accessioned2022-03-14T10:20:41Z
dc.date.available2022-03-14T10:20:41Z
dc.date.issued2021-12
dc.identifier.issn2073-4360
dc.identifier.urihttp://hdl.handle.net/10498/26416
dc.description.abstractA disposable colour-changeable optical sensor based on an interesting polymer inclusion-membrane (PIM) was designed to determine Cd(II) ions in aqueous medium. The Schiff base 2-acetylpyridine benzoylhydrazone (2-APBH) immobilised on the polymer membrane was used as a sensing molecule. The amounts of the PIM components were optimised by a 3(2) fractional factorial design with two central points and two blocks. The best optical sensor composition consisted of 2.5 g of poly(vinylchloride) (PVC) as a base polymer, 3 mL of tributyl phosphate (TBP) as a plasticiser, and 0.02 g of 2-APBH as a reagent. The sensor showed a good linear response in the range from 0.02 mg L-1 (limit of detection) to 1 mg L-1 of Cd(II) under the following experimental conditions: pH 9.5 (adjusted using ammonium chloride buffer solution at 0.337 mol L-1), 60 min of exposure time plus 2 min of sonication (pulses at 2 s intervals), and 10 min of short-term stability. The relative standard deviation of the method was determined to be 4.04% for 0.4 mg L-1 of Cd(II). The optical sensor was successfully applied to the determination of Cd(II) in natural-water and art-paint samples.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourcePolymers 2021, 13(24), 4414es_ES
dc.subjectpolymer-inclusion membranees_ES
dc.subjectCd(II) ions determinationes_ES
dc.subjectoptical sensores_ES
dc.subjectPVC matrixes_ES
dc.subject2-acetylpyridine benzoylhydrazonees_ES
dc.titleSensing Cd(II) Using a Disposable Optical Sensor Based on a Schiff Base Immobilisation on a Polymer-Inclusion Membrane. Applications in Water and Art Paint Sampleses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/polym13244414


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Atribución 4.0 Internacional