dc.description.abstractWeldment inspection is a critical process in the metal industry. It is first conducted visually, then manually and finally using instrumental techniques such as ultrasound. We made one hundred metal inert/active gas (MIG/MAG) weldments on plates of naval steel S275JR+N with no defects, and inducing pores, slag intrusion and cracks. With the objective of the three-dimensional reconstruction of the welding defects, phased array ultrasound inspections were carried out. Error-free weldment probes were used to provide the noise level. The results can be summarized as follows. (i) The top view obtained from the phased array provided no conclusive information about the welding defects. The values of the echo amplitudes were about 70 mV for pores and cracks, and greater than 150 mV for slag intrusion, all of which showed great variability. (ii) The sectional data did not lie at the same depths and they needed to be interpolated. (iii) The interpolated sectional views, or C-scans, allowed the computation of top views at any depth, as well as the three-dimensional reconstruction of the defects. (iv) The use of the simplest tool, consisting of the frequency histogram and its statistical moments, was sufficient to classify the defects. The mean echo amplitudes were 33 mV for pores, 72.16 mV for slag intrusion and 43.19 mV for cracks, with standard deviations of 8.84 mV, 24.64 mV and 12.39 mV, respectively. These findings represent the first step in the automatic classification of welding defects.es_ES
dc.description.sponsorshipThis research was funded by CEI.MAR Cadiz, 2020-PR003.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceMaterials, Vol. 15, Núm. 8es_ES
dc.subjectMIG/MAG weldinges_ES
dc.subjectultrasound inspectiones_ES
dc.subjectphased arrayes_ES
dc.subjectdigital imageses_ES
dc.titleA New Insight on Phased Array Ultrasound Inspection in MIG/MAG Weldinges_ES