Show simple item record

dc.contributor.authorPastor Fernández, Andrés 
dc.contributor.authorCerezo Narváez, Alberto 
dc.contributor.authorMontero Gutiérrez, María de la Paz
dc.contributor.authorBallesteros Pérez, Pablo 
dc.contributor.authorOtero Mateo, Manuel 
dc.contributor.otherIngeniería Mecánica y Diseño Industriales_ES
dc.date.accessioned2022-06-14T12:28:21Z
dc.date.available2022-06-14T12:28:21Z
dc.date.issued2022-04
dc.identifier.issn2076-3417
dc.identifier.urihttp://hdl.handle.net/10498/26945
dc.description.abstractIn the COVID-19 era, a direct relationship has been consolidated between the concentration of the pollutant carbon dioxide (CO2) and indoor disease transmission. For reducing its spread, recommendations have been established among which air renewal is a key element to improve indoor air quality (IAQ). In this study, a low-cost CO2 measurement device was designed, developed, assembled, prototyped, and openly programmed so that the IAQ can be monitored remotely. In addition, this clonic device was calibrated for correct data acquisition. In parallel, computational fluid dynamics (CFD) modeling analysis was used to study the indoor air flows to eliminate non-representative singular measurement points, providing possible locations. The results in four scenarios (cross ventilation, outdoor ventilation, indoor ventilation, and no ventilation) showed that the measurements provided by the clonic device are comparable to those obtained by laboratory instruments, with an average error of less than 3%. These data collected wirelessly for interpretation were evaluated on an Internet of Things (IoT) platform in real time or deferred. As a result, remaining lifespan of buildings can be exploited interconnecting IAQ devices with other systems (as HVAC systems) in an IoT environment. This can transform them into smart buildings, adding value to their refurbishment and modernization.es_ES
dc.description.sponsorshipAll authors acknowledge the help received by the research group TEP-955 from the PAIDI, the ERGOMET Project of the Program for the Promotion of Research Activity of the UCA, the Project "Design of a low-cost non-invasive ergonomic capture system for the analysis of musculoskeletal disorders" of the Program for the Promotion of Research and Transfer of the UCA and the National Plan Research Project PID2019-108669RB-100/AEI/10.13039/501100011033.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceApplied Sciences (Switzerland), Vol. 12, Núm. 8es_ES
dc.subjectindoor air quality (IAQ)es_ES
dc.subjectsmart buildinges_ES
dc.subjectsustainable development goals (SDGs)es_ES
dc.subjectCOVID-19es_ES
dc.subjectCO2es_ES
dc.subjectrefurbishmentes_ES
dc.titleUse of Low-Cost Devices for the Control and Monitoring of CO2 Concentration in Existing Buildings after the COVID Eraes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/app12083927
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2019-108669RB-I00/ES/DERECHO E INTELIGENCIA ARTIFICIAL: NUEVOS HORIZONTES JURIDICOS DE LA PERSONALIDAD Y LA RESPONSABILIDAD ROBOTICAS/es_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Atribución 4.0 Internacional
This work is under a Creative Commons License Atribución 4.0 Internacional