Show simple item record

dc.contributor.authorVera Jiménez, José Carlos 
dc.contributor.authorMeléndez Sánchez, Felipe
dc.contributor.authorÁlvarez Saura, José Ángel 
dc.contributor.authorAyuso Vilacides, Jesús 
dc.contributor.otherQuímica Físicaes_ES
dc.date.accessioned2022-09-29T11:55:51Z
dc.date.available2022-09-29T11:55:51Z
dc.date.issued2022-06
dc.identifier.issn1660-4601
dc.identifier.urihttp://hdl.handle.net/10498/27340
dc.description.abstract(1) Background: a set of ergonomic parameters that are relevant for risk assessment methods for the prevention of occupational risks, such as REBA or NIOSH, have been measured by means of inertial sensors that allow capturing the movements of the human body. These methods base their assessment on a number of postural and dynamic parameters. In the case of police physical intervention techniques, trunk, legs, arms, forearms and wrists angles, joint contact force and sheer force at the L5-Pelvic junction, asymmetry (angle and factor), and muscle power are the more relevant parameters to be considered. (2) Method: The data have been collected by means of a motion capture suit equipped with 19 inertial sensors. The large amount of data and the 3-dimensional plots have been managed by a powerful software package specific for ergonomic analysis. The police physical intervention technique used was OTP. (3) Results: Five ergonomic parameters in a traditional police physical intervention technique have been analyzed. REBA scores and ergonomic metrics have been recorded and discussed with some prevention risk limits from the literature. (4) Conclusions: the usage of inertial sensors to capture the movements in OTPs provides a new and quite an efficient viewpoint for occupational risk research studies.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceInternational Journal of Environmental Research and Public Health, Vol. 19, Núm. 11es_ES
dc.subjectergonomices_ES
dc.subjectoccupational risk preventiones_ES
dc.subjectpolice physical interventiones_ES
dc.subjectuse of forcees_ES
dc.subjectoperational tactical procedurees_ES
dc.subjectmotion capture technologyes_ES
dc.titleAn Analysis of Biomechanical Parameters in OTP Police Physical Intervention Techniques for Occupational Risk Preventiones_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/ijerph19116615
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//DER2012-35997-C03-03/ES/ESTUDIO DE LOS MATERIALES DE LA DEFENSAS POLICIALES Y POSIBLES MEJORA/es_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Atribución 4.0 Internacional
This work is under a Creative Commons License Atribución 4.0 Internacional