dc.description.abstractObjective To investigate the eddy current heating that occurs in metallic biliary stents during magnetic hyperthermia treatments and to assess whether these implants should continue to be an exclusion criterion for potential patients. Methods Computer simulations were run on stent heating during the hyperthermia treatment of local pancreatic tumors (5-15 mT fields at 300 kHz for 30 min), considering factors such as wire diameter, type of stent alloy, and field orientation. Maxwell's equations were solved numerically in a bile duct model, including the secondary field produced by the stents. The heat exchange problem was solved through a modified version of the Pennes' bioheat equation assuming a temperature dependency of blood perfusion and metabolic heat. Results The choice of alloy has a large impact on the stent heating, preferring those having a lower electrical conductivity. Only for low field intensities (5 mT) and for some of the bile duct tissue layers the produced heating can be considered safe. The orientation of the applied field with respect to the stent wires can give rise to the onset of regions with different heating levels depending on the shape that the stent has finally adopted according to the body's posture. Bile helps to partially dissipate the heat that is generated in the lumen of the bile duct, but not at a sufficient rate. Conclusion The safety of patients with pancreatic cancer wearing metallic biliary stents during magnetic hyperthermia treatments cannot be fully assured under the most common treatment parameters.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherTAYLOR & FRANCIS LTDes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceInternational Journal of Hyperthermia, Vol. 39, Núm. 1, pp. 1222-1232es_ES
dc.subjectBiliary stentes_ES
dc.subjectmagnetic hyperthermiaes_ES
dc.subjecteddy currentses_ES
dc.subjectelectromagnetic dosimetryes_ES
dc.subjectin silicoes_ES
dc.titleHeating of metallic biliary stents during magnetic hyperthermia of patients with pancreatic ductal adenocarcinoma: an in silico studyes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1080/02656736.2022.2121863
dc.relation.projectIDinfo:eu-repo/grantAgreement/EC/H2020/685795/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2020-117544RB-I00/ES/NANOBOMBA TERMOFORETICA DIRIGIDA Y CELULAS CAR MONITORIZADAS POR NANOPARTICULAS COMO TERAPIA INMUNOLOGICA COMBINADA/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI//CEX2020-001039-Ses_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/RED2018-102626-Tes_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/MAT2017-85617-R/ES/NANOMATERIALES FUNCIONALES PARA LA VERIFICACION DE PREDICCIONES IN SILICO DE NANOTERMOMETRIA E HIPERTERMIA MAGNETICA/es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//RYC2018-025253-Ies_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Atribución 4.0 Internacional