Show simple item record

dc.contributor.authorMarín Jiménez, Nuria 
dc.contributor.authorSánchez Parente, Sandra 
dc.contributor.authorExpósito Carrillo, Pablo
dc.contributor.authorJiménez Iglesias, José 
dc.contributor.authorÁlvarez Gallardo, Inmaculada Concepción 
dc.contributor.authorCuenca García, María Magdalena 
dc.contributor.authorCastro Piñero, José 
dc.contributor.otherDidáctica de la Educación Física, Plástica y Musicales_ES
dc.date.accessioned2023-06-06T10:08:12Z
dc.date.available2023-06-06T10:08:12Z
dc.date.issued2023-03
dc.identifier.issn1440-2440
dc.identifier.urihttp://hdl.handle.net/10498/28760
dc.description.abstractObjectives: To analyze the criterion-related validity and the reliability of fitness field tests for evaluating cardiorespiratory fitness in adults, by sex, age, and physical activity level. Design: Cross-sectional. Methods: During 3 weeks, sociodemographic, anthropometric measurements, a treadmill maximal test, the 2-km walk test, and the 20-m SRT were performed in 410 adults aged 18–64 years. Measured and estimated VO2max (by Oja's and Leger's equations) were analyzed. Results: Measured VO2max was associated with estimated VO2max by the 2-km walk test and 20-m SRT (r = 0.784 and r = 0.875, respectively; both p < 0.01). Bland–Altman analysis showed a mean difference of −0.30 ml* kg−1 * min−1 (p < 0.001, d = −0.141) in the 2-km walk test, and 0.86 ml* kg−1 * min−1 (p = 0.051) in the 20-m SRT. Significant mean differences between test and retest were found in the time to complete the 2-km walk test (−1.48 ± 0.51 s, p = 0.004, d = −0.014) and in the final stage reached in the 20-m SRT (0.04 ± 0.01, p = 0.002, d = 0.015). Non-significant differences were found between test and retest in the estimated VO2max by Oja's (−0.29 ± 0.20 ml* kg−1 * min−1 , p > 0.05) and Leger's eqs. (0.03 ± 0.04 ml* kg−1 * min−1 , p > 0.05). Moreover, both test results and estimated VO2max equations showed a high test–retest reliability. Conclusions: Both tests were valid and reliable for evaluating cardiorespiratory fitness in adults aged 18–64 years, regardless of sex, age, and physical activity level.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceJournal of Science and Medicine in Sport (2023)es_ES
dc.subjectFields testses_ES
dc.subjectCardiorespiratory fitness testes_ES
dc.subjectValidityes_ES
dc.subjectReproducibilityes_ES
dc.subjectAdultses_ES
dc.titleCriterion-related validity and reliability of the 2-km walk test and the 20-m shuttle run test in adults: The role of sex, age and physical activity leveles_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/j.jsams.2023.03.005
dc.type.hasVersionVoRes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional