Show simple item record

dc.contributor.authorMendiguchía Martínez, Carolina 
dc.contributor.authorMoreno Aguilar, Carlos 
dc.contributor.authorSilva García, Macarena
dc.contributor.otherQuímica Analíticaes_ES
dc.date.accessioned2023-09-06T11:29:02Z
dc.date.available2023-09-06T11:29:02Z
dc.date.issued2022-12-21
dc.identifier.issn2077-0375
dc.identifier.urihttp://hdl.handle.net/10498/29159
dc.description.abstractElectromembranes increase the efficiency of metal transport in liquid-phase microextraction systems by applying an electric potential, which accelerates the transport. Nevertheless, to get high extraction percentages in short extraction times it is necessary to take into account a great variety of factors, and multivariate optimization techniques are the best alternative to determine the most influential variables and to optimize the extraction process. In this work, a fractional factorial design was applied to determine the most influential variables in the extraction of silver by electromembranes. Thus, the effect of tri-isobutylphosphine sulphide (Cyanex 471x) concentration in the organic solution, sodium thiosulphate concentration in the acceptor solution, nitrate concentration in the sample solution, extraction time, stirring rate and electric potential on the enrichment factor were studied. Once the most important variables were selected, a small composite design (Draper–Lin) was used to obtain their optimal values to maximize the enrichment factor. Under these conditions, an experimental enrichment factor of 49.91 ± 3.95 was achieved after 22 min. Finally, the effect of saline matrix on the enrichment factor was tested and the optimized system was successfully applied to analyse silver concentrations at ultratrace levels, within the range of 7–29 ng·L−1 in different real seawater sampleses_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceMembranes. Vol. 13, nº 1, january 2023, 11es_ES
dc.subjectDraper–Lin designes_ES
dc.subjectelectromembraneses_ES
dc.subjecthollow-fibre liquid-phase microextractiones_ES
dc.subjectseawateres_ES
dc.subjectsilveres_ES
dc.subjecttri-isobutylphosphine sulphidees_ES
dc.titleAnalytical Performance of Electromembranes as a Tool for Nanoconcentrations of Silver in Waterses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.description.physDesc9 páginases_ES
dc.identifier.doi10.3390/membranes13010011
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//CTM2013-47549-P/ES/NUEVOS SISTEMAS PARA LA CUANTIFICACION DE METALES TRAZA EN AGUAS BASADOS EN MICROSISTEMAS CAPILARES. AUNANDO EFICACIA, APLICACION Y SOSTENIBILIDAD/ es_ES
dc.type.hasVersionVoRes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Atribución 4.0 Internacional
This work is under a Creative Commons License Atribución 4.0 Internacional