• español
    • English
  • Login
  • español 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Comunidades y colecciones
Ver ítem 
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
  •   RODIN Principal
  • Producción Científica
  • Artículos Científicos
  • Ver ítem
JavaScript is disabled for your browser. Some features of this site may not work without it.

Unravelling the impact of courtyard geometry on cooling energy consumption in buildings

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/29417

DOI: 10.1016/j.buildenv.2023.110349

ISSN: 0360-1323

Ficheros
2023_0585.pdf (7.355Mb)
Estadísticas
Ver estadísticas
Métricas y Citas
 
Compartir
Exportar a
Exportar a MendeleyRefworksEndNoteBibTexRIS
Metadatos
Mostrar el registro completo del ítem
Autor/es
Diz Mellado, Eduardo MaríaAutoridad UCA; Ruiz Pardo, ÁlvaroAutoridad UCA; Rivera Gómez, Carlos; Sánchez de la Flor, Francisco JoséAutoridad UCA; Galán Marín, Carmen
Fecha
2023-04-24
Departamento/s
Máquinas y Motores Térmicos
Fuente
Building and Environment. Vol, 237, 1 June 2023, 110349
Resumen
At present, the energy used for air conditioning in buildings in urban areas accounts for over 36% of total global energy consumption. Energy efficiency has become a critical factor in the urban planning of cities worldwide. Courtyard buildings in hot cities are a prime example of the approach used in traditional vernacular architecture to mitigate the effects of extreme weather. However, given the challenge of guaranteeing accurate modelling of microclimates within these courtyards, their impact on energy demand in buildings has been routinely over-looked by energy certification tools. This work examines three empirical case studies selected in Seville city (Spain), where temperatures during the summer months are extreme. The case studies selected display distinct geometric variations, and the primary objective of the research is to assess the influence of this geometric factor on the cooling energy demand of the building indoors. To achieve this, a validated methodology combining experimental and numerical data was implemented to evaluate the energy performance of buildings with courtyards. Different simulations were conducted to detect the impact of individual courtyard features. The results show a reduction in cooling demand of 8-18% depending on the geometry of the courtyard. Analysis was also carried out on the influence of the floor level and the orientation of adjacent rooms, revealing differences of 15% and 22%, respectively. The main conclusion of the research is that the use of courtyards as functional devices, paying particular attention to their geometry, is a key factor in the cooling energy demand of buildings.
Materias
Building performance simulation; Building energy modelling (BEM); Building energy demand; Passive cooling; Courtyards; Microclimate
Colecciones
  • Artículos Científicos [11777]
Atribución 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Atribución 4.0 Internacional

Listar

Todo RODINComunidades y ColeccionesPor fecha de publicaciónAutoresTítulosMateriasEsta colecciónPor fecha de publicaciónAutoresTítulosMaterias

Mi cuenta

AccederRegistro

Estadísticas

Ver Estadísticas de uso

Información adicional

Acerca de...Deposita en RODINPolíticasNormativasDerechos de autorEnlaces de interésEstadísticasNovedadesPreguntas frecuentes

RODIN está accesible a través de

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Académico

Enlaces de interés

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

ContactoSugerenciasAtención al Usuario