Mostrar el registro sencillo del ítem

dc.contributor.authorFernández Zacarías, Francisco 
dc.contributor.authorPuyana Romero, Virginia 
dc.contributor.authorHernández Molina, Ricardo 
dc.contributor.otherIngeniería Mecánica y Diseño Industriales_ES
dc.contributor.otherMáquinas y Motores Térmicoses_ES
dc.date.accessioned2023-10-30T12:15:34Z
dc.date.available2023-10-30T12:15:34Z
dc.date.issued2022-09-21
dc.identifier.issn2624-599X
dc.identifier.urihttp://hdl.handle.net/10498/29533
dc.description.abstractBackground: It is known that high noise levels can be harmful to preterm infants, causing physiological and psychological disorders. It is also known that premature babies spend a lot of time in an incubator. In this sense, many studies show that incubator noise levels can range from 45 to 70 dB. However, these differences in noise levels depend, fundamentally, on the wide range of methodology that can be used. This study aims to know the levels of noise from a fan in the incubator itself and how much it can isolate the noises coming from the outside. Methods: For this purpose, the noise levels of three incubators were measured within a sound-dampened booth for free-field audiometry. For the emission of acoustic energy, a pink noise generator was used; likewise, two microphones were placed, one inside the incubator cabin and the other outside, to determine the acoustic insulation levels of the tested incubators. Results: The incubators produced equivalent continuous sound pressure levels between 53.5 and 58 dB. Acoustic insulation analysis showed that levels varied from one incubator to another, between 5.2 and 10.4 dB. Conclusions: It is necessary to improve the acoustic insulation inside the incubator cabin and to reduce the noise levels of the motor fan. On the other hand, although the incubators are meeting the noise criteria set out in the IEC60601-2-19: 2009 standard of 60 dBA, under normal use conditions, they are still far from the limit recommended by the American Academy of Pediatrics (45 dBA).es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceAcoustics. Vol. 4, nº 4, December 2022, pp. 821 - 833es_ES
dc.subjectneonateses_ES
dc.subjectsound pressurees_ES
dc.subjectincubatorses_ES
dc.subjectnoise sourcees_ES
dc.subjectNICUes_ES
dc.subjectrisk in preterm infantses_ES
dc.titleThe Importance of Noise Attenuation Levels in Neonatal Incubatorses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.description.physDesc13 páginases_ES
dc.identifier.doi10.3390/acoustics4040049
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Atribución 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Atribución 4.0 Internacional