Show simple item record

dc.contributor.authorBarrera Izquierdo, Manuel 
dc.contributor.authorLira, Ignacio
dc.contributor.authorSánchez Sánchez, Marta 
dc.contributor.authorSuárez Llorens, Alfonso 
dc.contributor.otherEstadística e Investigación Operativaes_ES
dc.date.accessioned2023-12-21T14:51:14Z
dc.date.available2023-12-21T14:51:14Z
dc.date.issued2019
dc.identifier.issn0969-806X
dc.identifier.urihttp://hdl.handle.net/10498/29876
dc.description.abstractWe address the problem of evaluating measurements of radionuclide activity concentration from a robust Bayesian perspective. As shown in previous studies, Bayesian incorporation of available prior information on the activity levels, together with the measured values, leads in general to an improvement in the quality of radioanalytical results. Since the specific form of the employed prior is a critical aspect of the Bayesian framework, in the present paper we distort the prior distribution in order to evaluate how it influences the final activity estimate. We applied this procedure to inter-laboratory proficiency test data obtained by the laboratories that perform radiochemical analysis for the Spanish radioactive monitoring network. We found that in the present application the Bayesian methodology is indeed robust, as modifying the specific form of the prior has little effect on the activity estimate. Similar sensitivity analysis could be applied to the Bayesian evaluation of measurements of other quantities for which prior knowledge is available.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceRadiation Physics and Chemistry - 2019, Vol. 156 pp. 266–271es_ES
dc.subjectRobust Bayesian analysises_ES
dc.subjectRadiation measurementes_ES
dc.subjectClass of priorses_ES
dc.subjectRadionuclide analysises_ES
dc.subjectProficiency testses_ES
dc.subjectUncertainty of measurementes_ES
dc.titleBayesian treatment of results from radioanalytical measurements. Effect of prior information modification in the final value of the activityes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/j.radphyschem.2018.11.023
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/MTM2017-89577-P/ES/ORDENACIONES ESTOCASTICAS APLICADAS A LOS SEGUROS, LAS FINANZAS Y LA FIABILIDAD DE SISTEMAS/ es_ES
dc.type.hasVersionAMes_ES