| dc.contributor.author | Aliaño González, María José | |
| dc.contributor.author | Ferreiro González, Marta | |
| dc.contributor.author | Espada Bellido, Estrella | |
| dc.contributor.author | Fernández Barbero, Gerardo | |
| dc.contributor.author | Palma Lovillo, Miguel | |
| dc.contributor.other | Química Analítica | es_ES |
| dc.date.accessioned | 2024-01-12T11:07:44Z | |
| dc.date.available | 2024-01-12T11:07:44Z | |
| dc.date.issued | 2020-03-11 | |
| dc.identifier.issn | 0956-7135 | |
| dc.identifier.uri | http://hdl.handle.net/10498/29966 | |
| dc.description.abstract | According to European Union Regulation, honey is a food product whose composition cannot be modified. However, high-quality honey is often adulterated by adding sweeteners of other sugar compounds. This paper studies the suitability of Ion Mobility Spectra from generated headspace as a method for the detection and discrimination of honey adulterated by different substances. A Box-Behnken design in conjunction with a re sponse surface methodology was employed to optimize five different variables related to headspace generation
(incubation temperature, incubation time, injection volume, weight of the samples and pre-heating time). The resulting model showed a regression coefficient of R2 = 88.07%, it is therefore suitable for a reliable selection of the experimental variables. Repeatability and intermediate precision were also evaluated, and coefficients of variation below 5% were obtained (CV of 4.6% and 4.2% respectively). The developed method has been applied to different samples resulting for the mixture of honey and other sweeteners at different percentages (5%–50%) in an attempt to mimic the adulterated products that are more commonly found in the market. A thorough and exact classification (100%) with regards to the presence/absence of adulterant as well as the type of adulterant used has been achieved. A Partial Least Squares regression model was completed in order to determine the percentage of the different adulterants. The prediction error was below 4% in all the cases. These results de monstrate the applicability of the developed method for the detection and quantification of adulterated honey
with different adulterant contents. | es_ES |
| dc.format | application/pdf | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | Elsevier | es_ES |
| dc.source | Food Control 114 (2020) 107236 | es_ES |
| dc.subject | Honey | es_ES |
| dc.subject | Adulteration | es_ES |
| dc.subject | Sweeteners | es_ES |
| dc.subject | Ion mobility spectrometry | es_ES |
| dc.subject | Sum spectrum | es_ES |
| dc.subject | Chemometric | es_ES |
| dc.subject | Quantification | es_ES |
| dc.title | Novel method based on ion mobility spectroscopy for the quantification of adulterants in honeys | es_ES |
| dc.type | journal article | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.identifier.doi | 10.1016/J.FOODCONT.2020.107236 | |
| dc.type.hasVersion | AM | es_ES |