Show simple item record

dc.contributor.authorMontero Gutiérrez, María de la Paz
dc.contributor.authorSánchez Ramos, José
dc.contributor.authorGuerrero Delgado, MCarmen
dc.contributor.authorCerezo Narváez, Alberto 
dc.contributor.authorPalomo Amores, Teresa Rocío
dc.contributor.authorÁlvarez Domínguez, Servando
dc.contributor.otherIngeniería Mecánica y Diseño Industriales_ES
dc.contributor.otherMáquinas y Motores Térmicoses_ES
dc.dateinfo:eu-repo/date/embargoEnd/2025-11-15
dc.date.accessioned2024-01-12T12:26:12Z
dc.date.available2024-01-12T12:26:12Z
dc.date.issued2023-09-02
dc.identifier.issn0196-8904
dc.identifier.urihttp://hdl.handle.net/10498/29974
dc.description.abstractIn response to the challenges posed by climate change and the growing heat patterns in cities, this study addresses the design and implementation of climate shelters integrated into public transport stops through the installation of surface radiant cooling modules. The aim is to improve the thermal comfort of short-stay users in cities in hot, dry climates. To this end, a fully sensorized thermal camera was used in a controlled setting to simulate real outdoor climate conditions and evaluate the efficacy of the radiant system. The prototype was modelled and characterized by means of in situ measurements, paying special attention to the temperature and radiant heat flux. The radiant modules maintained a temperature between 18 ◦C and 20 ◦C, even under oppressive conditions, with over 50% of the cooling flux due to radiation. The radiative performance of the prototype did not increase proportionally with increased water flow, stabilizing at high flows. The analysis of the thermal comfort index showed a decrease in feelings of discomfort of between 40% and 50% when the modules reached the set point temperature. The study shows that implementing these climate shelters in public transport stops such a bus shelters is feasible in hot, dry climates. This may be an effective strategy for mitigating the effects of climate change in urban areas and can be applied in any city that suffers from recurring heatwaves, thereby improving living conditions for city goers.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceEnergy Conversion and Management - 2023, Vol. 296 pp. 117627es_ES
dc.subjectPublic transit infrastructurees_ES
dc.subjectUrban climate shelteres_ES
dc.subjectUHIes_ES
dc.subjectHeat sinkses_ES
dc.subjectThermal comfortes_ES
dc.subjectRadiant cooling solutiones_ES
dc.subjectFalling-filmes_ES
dc.titleNatural cooling solution for thermally conditioning bus stops as urban climate shelters in hot areas: Experimental proof of conceptes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/j.enconman.2023.117627
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PID2020-118972RB-I00/ES/METODOLOGIAS DE URBANIZACION RESILIENTE Y ACONDICIONAMIENTO NATURAL MEDIANTE SOLUCIONES BASADAS EN LA NATURALEZA Y EL PATRIMONIO CULTURAL PARA RECUPERAR LA VIDA EN LA CALLE/ es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/PLAN ESTATAL DE INVESTIGACIÓN CIENTÍFICA, TÉCNICA Y DE INNOVACIÓN 2021-2023/TED2021-130416B-I00es_ES
dc.type.hasVersionAMes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional