Show simple item record

dc.contributor.authorBrito, Javier
dc.contributor.authorAlmengló Cordero, Fernando 
dc.contributor.authorRamírez Muñoz, Martín 
dc.contributor.authorGómez Montes de Oca, José Manuel 
dc.contributor.authorCantero Moreno, Domingo 
dc.contributor.otherIngeniería Química y Tecnología de Alimentoses_ES
dc.date.accessioned2024-01-15T11:54:43Z
dc.date.available2024-01-15T11:54:43Z
dc.date.issued2017-09
dc.identifier.issn0268-2575
dc.identifier.urihttp://hdl.handle.net/10498/29997
dc.description.abstractBACKGROUND A high H2S elimination capacity has been achieved by anoxic biotrickling filters but accurate control of the nitrate dosage is required. Different control strategies have been used in biotrickling filters but proportional-integral-derivative (PID) control studies have not been reported to date. The aim of this study was to demonstrate the stability and robustness of PID control in an anoxic biotrickling filter. RESULTS Three PID tuning methods were tested: Ziegler–Nichols, Approximate M-constrained integral gain optimization (AMIGO), and maintained oscillation. The best results were obtained using PID control by the maintained oscillation method, where the system reached stabilization 0.41 h after the H2S inlet step. Moreover, the nitrate consumption was 15.4% lower than that without control. CONCLUSION The biotrickling filter operated with a PID control strategy proved to be highly stable and robust against the perturbations and disturbances evaluated. The control system was able to operate satisfactorily to a change in the set-point of the outlet H2S concentrations from 25 to 200 ppmV. The desulfurized biogas could be fed directly to an internal combustion engine or solid oxide fuel cell (SOFC) equipped with a zeolite clean unit. © 2017 Society of Chemical Industryes_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherWileyes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceJournal of Chemical Technology and Biotechnology, Vol. 92, Núm. 9, 2017, pp. 2369-2375es_ES
dc.subjectbiofiltration of waste gaseses_ES
dc.subjectbiogases_ES
dc.subjectenergyes_ES
dc.subjectprocess controles_ES
dc.subjectremovales_ES
dc.subjectenvironmental biotechnologyes_ES
dc.titlePID control system for biogas desulfurization under anoxic conditionses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1002/JCTB.5243
dc.relation.projectIDinfo:eu-repo/grantAgreement/MINECO//CTM2012-37927-C03-03/ES/MONITORIZACION, MODELIZACION Y CONTROL PARA LA OPTIMIZACION DE BIOFILTROS PERCOLADORES DE DESULFURACION ANOXICOS Y AEROBIOS/ es_ES
dc.type.hasVersionAMes_ES