Show simple item record

dc.contributor.authorFernández Banqué, F.
dc.contributor.authorRamos Lerate, Inmaculada Concepción 
dc.contributor.authorMartínez, J.C.
dc.contributor.authorBeltrán, D.
dc.contributor.authorBordas, J.
dc.contributor.authorKey, M.
dc.contributor.otherFísica Aplicadaes_ES
dc.date.accessioned2024-01-18T19:39:58Z
dc.date.available2024-01-18T19:39:58Z
dc.date.issued2007
dc.identifier.issn0168-9002
dc.identifier.urihttp://hdl.handle.net/10498/30106
dc.description.abstractMicro-pattern gas detectors (MPGD) could become suitable devices to carry out time-resolved X-ray diffraction experiments in the sub-millisecond time scale at synchrotron radiation facilities. Nevertheless, these devices are not free of problems. Among other problems are the build-up of ions in the detector components and the susceptibility of the materials in the structure to dielectric breakdown. Here, we present a new MPGD design we have called micro reading mesh chamber (MRMC). Its layout is based on a resistive anode, support pillars and a mesh formed by two planes of pick-up strips. In order to prevent charging up, a common problem with GEMs and MPGD in general, a minimum amount of dielectric material has been used in the design. The aim has been to avoid dielectric near the drift paths of the ions. To prevent dielectric breakdown, a resistive anode with guard rings at the base of the pillars has been designed. Finally, to improve the cathode signals quality, we use a mesh to read the avalanche. In this manner the size of the induced charge is larger than in more conventional eometries.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherELSEVIERes_ES
dc.sourceNucl. INSTRUMENTS METHODS Phys. Res. Sect. A-ACCELERATORS SPECTROMETERS Detect. Assoc. Equip., vol. 573, pp. 298–301, 2007,es_ES
dc.subjectX-ray detector; Gaseous detector; Position-sensitive detector; Sub-millisecond; MPGD; Synchrotron radiationes_ES
dc.subjectX-ray detectores_ES
dc.subjectGaseous detectores_ES
dc.subjectPosition-sensitive detectores_ES
dc.subjectSub-millisecondes_ES
dc.subjectMPGDes_ES
dc.subjectSynchrotron radiationes_ES
dc.titleNew micro-pattern gas detector based on a 2D position readout meshes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsclosed accesses_ES
dc.description.physDescArtículo de 4 páginases_ES
dc.identifier.doi10.1016/j.nima.2006.10.395
dc.type.hasVersionNAes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record