| dc.contributor.author | Toledo, J. | |
| dc.contributor.author | Beltrán, D. | |
| dc.contributor.author | Bordas, J. | |
| dc.contributor.author | Ramos Lerate, Inmaculada Concepción | |
| dc.contributor.author | Martínez, J.C. | |
| dc.contributor.author | Fernández, F. | |
| dc.contributor.other | Física Aplicada | es_ES |
| dc.date.accessioned | 2024-01-19T15:08:21Z | |
| dc.date.available | 2024-01-19T15:08:21Z | |
| dc.date.issued | 2004-08 | |
| dc.identifier.issn | 0018-9499 | |
| dc.identifier.uri | http://hdl.handle.net/10498/30131 | |
| dc.description.abstract | This article describes the functionality, implementation and performance of a PCI data acquisition board that can be used in conjunction with gas-filled detectors with delay line readout. The board combines a large on-board 256-MByte histogramming memory with a maximum 10-MHz count rate in
continuous operation and integrates the time frame generation, histogram building and buffering functionalities in a single PCI board, resulting in a fast, compact and cost-effective data acquisition solution for the Spanish beamline BM16 at ESRF. | es_ES |
| dc.format | application/pdf | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC, 445 HOES LANE, PISCATAWAY, NJ 08, USA | es_ES |
| dc.source | IEEE TRANSACTIONS ON NUCLEAR SCIENCE, VOL. 51, NO. 4, AUGUST 2004 | es_ES |
| dc.subject | Data acquisition | es_ES |
| dc.subject | delay-linereadout | es_ES |
| dc.subject | DMA | es_ES |
| dc.subject | histogramming | es_ES |
| dc.title | Fast and compact data acquisition for gas-filled detectors with delay line | es_ES |
| dc.type | journal article | es_ES |
| dc.rights.accessRights | closed access | es_ES |
| dc.description.physDesc | Artículo de 4 páginas | es_ES |
| dc.identifier.doi | 10.1109/TNS.2004.831627 | |
| dc.type.hasVersion | NA | es_ES |