| dc.contributor.author | Pinto Ganfornina, Juan José | |
| dc.contributor.author | Mendiguchía Martínez, Carolina | |
| dc.contributor.author | López López, José Antonio | |
| dc.contributor.author | Martín Barata, Mabel | |
| dc.contributor.author | Silva García, Macarena | |
| dc.contributor.author | Moreno Aguilar, Carlos | |
| dc.contributor.other | Química Analítica | es_ES |
| dc.date.accessioned | 2024-01-29T10:50:01Z | |
| dc.date.available | 2024-01-29T10:50:01Z | |
| dc.date.issued | 2023 | |
| dc.identifier.issn | 2077-0375 | |
| dc.identifier.uri | http://hdl.handle.net/10498/30365 | |
| dc.description.abstract | Due to its important environmental role, the analysis of trace metals in natural waters is
attracting increasing attention; consequently, faster and more accurate analytical methods are now
needed to reach even lower limits of detection. In this work, we propose the use of electro-membrane
extraction (EME) to improve analytical methods based on hollow fiber liquid phase micro-extraction
(HFLPME). Specifically, an EME-based method for the determination of trace Ni in seawater has been
developed, using an HFLPME system with di-2-ethylhexyl phosphoric acid (DEHPA) in kerosene as
a chemical carrier, followed by instrumental determination by graphite furnace atomic absorption
spectroscopy (GFAAS). Under optimum conditions, Ni was pre-concentrated 180 +/- 17 times after
15 min, using sample pH = 5.5, the concentration of DEHPA 0.9 M in the liquid membranes, and
1.9 M HNO3 in the acceptor solution, as well as an electric potential of 25 V with the sample being
stirred at 500 rpm. When compared with other HFLPME systems for pre-concentration of trace
Ni in seawater in the absence of electric potential, the enrichment factor was improved 2.2 times,
while the time of extraction was reduced an 89%. The limit of detection of the new method was
23.3 ng L-1, and both its applicability and accuracy were successfully evaluated by analyzing Ni
concentration in a seawater-certified reference material (BCR-403), showing the reliability of EME for
sample preparation in the determination of trace metals in marine water samples. | es_ES |
| dc.format | application/pdf | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | MDPI | es_ES |
| dc.source | Membranes - 2023, Vol. 13 n. 152 | es_ES |
| dc.subject | electro-membrane extraction | es_ES |
| dc.subject | nickel | es_ES |
| dc.subject | Seawater | es_ES |
| dc.subject | hollow fiber liquid phase micro-extraction | es_ES |
| dc.subject | di-2-ethylhexyl phosphoric acid (DEHPA) | es_ES |
| dc.title | Improvement of Advanced Sample Preparation Systems for the Determination of Trace Ni in Seawater by Electro-Membranes | es_ES |
| dc.type | journal article | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.identifier.doi | 10.3390/membranes13020152 | |
| dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//CTM2013-47549-P/ES/NUEVOS SISTEMAS PARA LA CUANTIFICACION DE METALES TRAZA EN AGUAS BASADOS EN MICROSISTEMAS CAPILARES. AUNANDO EFICACIA, APLICACION Y SOSTENIBILIDAD | es_ES |
| dc.relation.projectID | info:eu-repo/grantAgreement/AEI//PID2021-128642OB-I00 | es_ES |
| dc.type.hasVersion | VoR | es_ES |