Show simple item record

dc.contributor.authorFernández Zacarías, Francisco 
dc.contributor.authorBeira Jiménez, Juan Luis 
dc.contributor.authorBustillo Velázquez-Gaztelu, Pedro J.
dc.contributor.authorHernández Molina, Ricardo 
dc.contributor.authorLubián López, Simón Pedro 
dc.contributor.otherIngeniería Mecánica y Diseño Industriales_ES
dc.contributor.otherMáquinas y Motores Térmicoses_ES
dc.contributor.otherMaterno-Infantil y Radiologíaes_ES
dc.date.accessioned2024-01-31T09:36:44Z
dc.date.available2024-01-31T09:36:44Z
dc.date.issued2018-02-20
dc.identifier.issn2073-4360
dc.identifier.urihttp://hdl.handle.net/10498/30430
dc.description.abstractBackground Preterm infants usually have to spend a long time in an incubator, excessive noise in which can have adverse physiological and psychological effects on neonates. In fact, incubator noise levels typically range from 45 to 70 dB but differences in this respect depend largely on the noise measuring method used. The primary aim of this work was to assess the extent to which noise in an incubator comes from its own fan and how efficiently the incubator can isolate external noise. Methods Three different incubator models were characterized for acoustic performance by measuring their internal noise levels in an anechoic chamber, and also for noise isolation efficiency by using a pink noise source in combination with an internal and an external microphone that were connected to an SVAN958 noise analyzer. Results The incubators studied produced continuous equivalent noise levels of 53.5–58 dB and reduced external noise by 5.2–10.4 dB. Conclusions A preterm infant in an incubator is exposed to noise levels clearly exceeding international recommendations even though such levels usually comply with the limit set in the standard IEC60601-2-19: 2009 (60 dBA) under normal conditions of use.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceInternational Journal of Pediatric Otorhinolaryngology Volume 107, April 2018, Pages 150-154es_ES
dc.subjectnoise leveles_ES
dc.subjectneonatal incubatores_ES
dc.subjectnoise isolationes_ES
dc.titleNoise level in neonatal incubators: A comparative study of three modelses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsclosed accesses_ES
dc.identifier.doi10.1016/J.IJPORL.2018.02.013
dc.type.hasVersionVoRes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional