| dc.description.abstract | Background: Transcranial static magnetic field stimulation (tSMS) in humans reduces cortical excitability.
Objective: The objective of this study was to determine if prolonged tSMS (2 h) could be delivered safely in humans. Safety limits for this technique have not been described.
Methods: tSMS was applied for 2 h with a cylindric magnet on the occiput of 17 healthy subjects. We assessed tSMS-related safety aspects at tissue level by measuring levels of neuron-specific enolase (NSE, a marker of neuronal damage) and S100 (a marker of glial reactivity and damage). We also included an evaluation of cognitive side effects by using a battery of visuomotor and cognitive tests.
Results: tSMS did not induce any significant increase in NSE or S100. No cognitive alteration was detected.
Conclusions: Our data indicate that the application of tSMS is safe in healthy human subjects, at least within these parameters. | es_ES |
| dc.format | application/pdf | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | ELSEVIER SCIENCE BV | es_ES |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.subject | NIBS | es_ES |
| dc.subject | Neuron-specific enolase | es_ES |
| dc.subject | Repetitive transcranial magnetic stimulation (rTMS) | es_ES |
| dc.subject | S100 | es_ES |
| dc.subject | Safety | es_ES |
| dc.subject | Transcranial static magnetic field stimulation (tSMS) | es_ES |
| dc.title | Safety Study of Transcranial Static Magnetic Field Stimulation (tSMS) of the Human Cortex | es_ES |