Mostrar el registro sencillo del ítem

dc.contributor.authorGonzález Gorbeña, Eduardo
dc.contributor.authorPacheco, André
dc.contributor.authorPlomaritis, Theocharis 
dc.contributor.authorFerreira, O.
dc.contributor.authorSequeira, Cláudia
dc.contributor.otherFísica Aplicadaes_ES
dc.date.accessioned2024-02-09T11:31:08Z
dc.date.available2024-02-09T11:31:08Z
dc.date.issued2018
dc.identifier.issn0306-2619
dc.identifier.urihttp://hdl.handle.net/10498/31007
dc.description.abstractThis paper investigates the optimum tidal energy converter array density at a tidal inlet by applying surrogate-based optimisation. The SBO procedure comprises problem formulation, design of experiments, numerical simulations, surrogate model construction and constrained optimisation. This study presents an example for the Faro-Olhão Inlet in the Ria Formosa (Portugal), a potential site for tidal in-stream energy extraction. A 35 kW Evopod™ floating tidal energy converter from Oceanflow Energy Ltd. has been used for array size calculations considering two design variables: (1) number of array rows, and (2) number of tidal energy converter per row. Arrays up to 13 rows with 6–11 tidal energy converters each are studied to assess their impacts on array performance, inlets discharges and bathymetry changes. The analysis identified the positive/negative feedbacks between the two design variables in real case complex flow fields under variable bathymetry and channel morphology. The non-uniformity of tidal currents along the array region causes the variability of the resource in each row, as well as makes it difficult to predict the resultant array configuration interactions. Four different multi-objective optimisation models are formulated subject to a set of performance and environmental constraints. Results from the optimisation models imply that the largest array size that meets the environmental constraints is made of 5 rows with 6 tidal energy converter each and an overall capacity factor of 11.6% resulting in an energy production of 1.01 GWh year−1. On the other hand, a higher energy production (1.20 GWh year−1) is achieved by an optimum array configuration, made of 3 rows with 10 tidal energy converters per row, which maximises power output satisfying environmental and performance restrictions. This optimal configuration permits a good level of energy extraction while having a reduced effect on the hydrodynamic functioning of the multi-inlet system. These results prove the suitability and the potential wide use of the surrogate-based optimisation method to define array characteristics that enhance power production and at the same time respect the environmental surrounding conditions.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceApplied Energy, 2018, Vol. 232 pp. 292-311es_ES
dc.titleEstimating the optimum size of a tidal array at a multi-inlet system considering environmental and performance constraintses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsclosed accesses_ES
dc.identifier.doi10.1016/J.APENERGY.2018.09.204
dc.relation.projectIDPTDC/AAG-TEC/1710/2014es_ES
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional