Mostrar el registro sencillo del ítem

dc.contributor.authorRodríguez Montaño, Víctor Manuel 
dc.contributor.authorBeira Jiménez, Juan Luis 
dc.contributor.authorHernández Molina, Ricardo 
dc.contributor.authorFernández Zacarías, Francisco 
dc.contributor.authorCueto Ancela, José Luis 
dc.contributor.authorBustillo Velázquez-Gaztelu, Pedro Jesus
dc.contributor.authorLubián López, Simón 
dc.contributor.otherIngeniería Eléctricaes_ES
dc.contributor.otherMáquinas y Motores Térmicos
dc.contributor.otherIngeniería Mecánica y Diseño Industrial
dc.contributor.otherCiencias y Técnicas de la Navegación y Construcciones Navales
dc.contributor.otherMaterno-Infantil y Radiología
dc.date.accessioned2024-02-09T14:10:23Z
dc.date.available2024-02-09T14:10:23Z
dc.date.issued2019-06-16
dc.identifier.isbn978-090988203-7
dc.identifier.issn0736-2935
dc.identifier.urihttp://hdl.handle.net/10498/31076
dc.descriptionEsta aportación esta indexada en Scopus, Researchgate, Scimago, y Google Scholar.es_ES
dc.description.abstractThe objective of this work focuses on the frequency analysis of the noise suffered by neonatal patients inside the incubators located in Neonatal Intensive Care Units (NICU). As a rule, noise has been evaluated in relation to the equivalent continuous level per hour (LAeq,1h). Different international organizations, such as the American Academy of Pediatrics, establish a recommended limit for this index of 45 dBA. However, according to the existing literature, the audible range of the neonate is between 400 Hz and 4 kHz, coinciding with the range of human speech intelligibility frequencies. For this, we have carried out a series of acoustic measurements that allow us to evaluate the noise in the NICU of the Hospital Universitario Puerta del Mar in Cádiz, which allows us to show that the indicator used LAeq,1h must be complemented with a study and frequency analysis to determine acoustic quality and protect to neonates.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherInternational Institute of Noise Control Engineering (I-INCE)es_ES
dc.sourceInterNoise19. Pages 1998-2994, pp.2891-2901es_ES
dc.subjectFrequencies, Noise, Incubatores_ES
dc.titleEnvironmental sound spectral analysis suffered by neonatal patients. Case study: Nicu of Hospital Universitario Puerta del Mar (Cádiz).es_ES
dc.typeconference outputes_ES
dc.rights.accessRightsclosed accesses_ES
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem