dc.description.abstractThe present work introduces two novel approaches to fabricate simple and cost-effective pH and temperature probes. Sinusoidal voltage methodologies were employed to electrodeposit polyaniline (PANI) at different growth times (10–20 min) on the surface of an affordable Sonogel-Carbon electrode to conform a robust pH sensor. The presence of PANI and its phases were corroborated by electrochemical means. The sensibility, reversibility and selectivity of the produced sensor were very adequate to apply it in physiological samples. In this regard, the proposed sensor was evaluated in artificial blood serum as well as untreated plasma samples obtaining outstanding results in comparison with a gold reference technique (error <2 %). In addition, a new composite sonogel material, intrinsically modified with multiwalled carbon nanotubes, was attached on top of an electrode couple to one-step fabricate a new temperature probe, relating resistance of the probe with the surroundings temperature. In this case, an optical microscopy characterization was performed to study the sturdiness of the layer. Remarkably, suitable results in terms of sensitivity and selectivity were obtained. The probes were assessed in artificial and untreated plasma samples as well, with the corresponding validation step (error <1 %) by using a commercial temperature probe.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceTalanta, Vol. 270, 2024es_ES
dc.subjectMultiwalled carbon nanotubeses_ES
dc.subjectpHes_ES
dc.subjectPolyanilinees_ES
dc.subjectSinusoidal voltageses_ES
dc.subjectSonogel-carbon electrodeses_ES
dc.subjectTemperaturees_ES
dc.titleSimple and cost-effective pH and T sensors from top to bottom: New chemical probes based on sonogel-carbon transducers for plasma analyseses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/J.TALANTA.2023.125603
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2021-2023/PID2021-122578NB-I00/ES/DESARROLLO Y VALIDACION DE UN DISPOSITIVO MULTIPARAMETRICO PARA EL ANALISIS EN CONTINUO DE MUESTRAS BIOMEDICAS/es_ES
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional