Show simple item record

dc.contributor.authorSilva García, Macarena
dc.contributor.authorMendiguchía Martínez, Carolina 
dc.contributor.authorMoreno Aguilar, Carlos 
dc.contributor.authorKuban, Pavel
dc.contributor.otherQuímica Analíticaes_ES
dc.date.accessioned2024-07-08T07:16:00Z
dc.date.available2024-07-08T07:16:00Z
dc.date.issued2018
dc.identifier.issn0173-0835
dc.identifier.issn1522-2683
dc.identifier.urihttp://hdl.handle.net/10498/32874
dc.descriptionThis is the pre-peer reviewed version of the following article: Silva, M., Mendiguchía, C., Moreno, C. and Kubáň, P. (2018), Electromembrane extraction and capillary electrophoresis with capacitively coupled contactless conductivity detection: Multi-extraction capabilities to analyses trace metals from saline samples. ELECTROPHORESIS, 39: 2152-2159, which has been published in final form at [https://doi.org/10.1002/elps.201800125]. This article may be used for non-commercial purposes in accordance with Wiley Terms and Conditions for Use of Self-Archived Versionses_ES
dc.description.abstractSimultaneous electromembrane extraction (EME) of six trace metal cations (Cu2+, Zn2+, Co2+, Ni2+, Pb2+, Cd2+) from saline samples was investigated. CE with capacitively coupled contactless conductivity detection (C4D) was used to determine the metals in acceptor solutions due to its excellent compatibility with the minute volumes of acceptor solutions. Bis(2-ethylhexyl)phosphate (DEHPA) was selected as a suitable nonselective modifier for EME transport of target metal cations. Both, the individual effect of each major inorganic cation (Na+, K+, Ca2+, Mg2+) and their synergistic effect on EME of the trace metal cations were evaluated. In both cases, a decrease in extraction efficiency was observed when major inorganic cations were present in the sample. This effect was more significant for Ca2+ and Mg2+. The system was optimized for simultaneous extractions of the six target metals from saline samples (50 mM Na+, 5 mM Mg2+, 1 mM K+, and 1 mM Ca2+) and following EME conditions were applied. Organic phase consisted of 1-nonanol containing 1% (v/v) DEHPA, acceptor solution was 1 M acetic acid (HAc) and sample pH was adjusted to 5. Sample was stirred at 750 rpm and EMEs were carried out at extraction potential of 10 V for 20 min. The method presented a repeatability between 8 and 21.8% (n = 5), good linearity in 0.5–10 μM concentration range (R2 = 0.987-0.999) and LOD better than 2.6 nM. Applicability of the EME–CE–C4D method to the analyses of metal cations in drinking water, seawater, and urine samples was also demonstrated.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceElectrophoresis Vol 39, n 16, pp 2152 - 2159es_ES
dc.subjectCEes_ES
dc.subjectDEHPAes_ES
dc.subjectElectromembrane extractiones_ES
dc.subjectMajor inorganic cationses_ES
dc.subjectMetal cationses_ES
dc.subjectSaline sampleses_ES
dc.titleElectromembrane extraction and capillary electrophoresis with capcitively coupled contactless conductivity detection: multi-extraction capabilities to analyse trace metals from saline sampleses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1002/elps.201800125
dc.type.hasVersionAOes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional