Mostrar el registro sencillo del ítem

dc.contributor.authorGranado Castro, María Dolores 
dc.contributor.authorDíaz de Alba, Margarita Isabel 
dc.contributor.authorChinchilla Real, I.
dc.contributor.authorGalindo Riaño, María Dolores 
dc.contributor.authorGarcía Vargas, Manuel
dc.contributor.authorCasanueva Marenco, María José 
dc.contributor.otherQuímica Analíticaes_ES
dc.date.accessioned2024-09-18T10:23:18Z
dc.date.available2024-09-18T10:23:18Z
dc.date.issued2019
dc.identifier.issn0039-9140
dc.identifier.urihttp://hdl.handle.net/10498/33260
dc.description.abstractA tandem system based on the coupling of a bulk liquid membrane and a flow injection analysis for the separation, preconcentration and spectrophotometric determination of copper in saline water is presented. The ligand pyridine-2-acetaldehyde benzoylhydrazone has been used as a carrier in the liquid membrane as well as a spectrophotometric reagent for UV–VIS detection. Simultaneous and sequential experimental designs were used to optimise the chosen variables of each technique, respectively. The metal was separated and preconcentrated from the sample with an efficiency of 100.5 ± 0.9% and a metal preconcentration factor of 16.1. The on-line FIA determination was accomplished after metal complexation by the reagent at pH 3. A linear response was obtained in a range from 6.9 to 984.5 μg L–1 Cu(II), providing a detection limit of 1.8 μg L–1. Saline matrix and other metal ions were not cause of interferences with relative errors below 4.6% for 50 μg L−1 of Cu(II) determination. The proposed tandem system was successfully tested using a TMDA-62 certified reference material providing a relative error of +1.9%; it was also applied to the Cu(II) determination in coastal seawater samples with low relative errors ranging from −3.8% to 0.0% (using DPASV as reference method).es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceTalanta, 192 (2019) 374-379es_ES
dc.subjectcopperes_ES
dc.subjectseawateres_ES
dc.subjectliquid membranees_ES
dc.subjectpyridine-2-acetaldehyde benzoylhydrazonees_ES
dc.subjectflow injection analysis (FIA),es_ES
dc.subjectpreconcentrationes_ES
dc.titleCoupling liquid membrane and flow-injection technique as an analytical strategy for copper analysis in saline wateres_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/j.talanta.2018.09.040
dc.type.hasVersionSMURes_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional