Mostrar el registro sencillo del ítem

dc.contributor.authorAlbendín García, María Gemma 
dc.contributor.authorLópez López, José Antonio 
dc.contributor.authorPinto Ganfornina, Juan José 
dc.contributor.otherAnatomía Patológica, Biología Celular, Histología, Historia de la Ciencia, Medicina Legal y Forense y Toxicologíaes_ES
dc.contributor.otherQuímica Analíticaes_ES
dc.date.accessioned2024-09-23T11:10:30Z
dc.date.available2024-09-23T11:10:30Z
dc.date.issued2016
dc.identifier.issn0003-2697
dc.identifier.urihttp://hdl.handle.net/10498/33295
dc.description.abstractTrends in the analysis of trace metals in natural waters are mainly based on the development of sample treatment methods to isolate and pre-concentrate the metal from the matrix in a simpler extract for further instrumental analysis. However, direct analysis is often possible using more accessible techniques such as spectrophotometry. In this case a proper ligand is required to form a complex that absorbs radiation in the UV-Vis spectrum. In this sense, the hydrazone derivative, di-2-pyridylketone benzoylhydrazone (dPKBH) forms complexes with Cu and V that absorb light at 370 nm and 395 nm respectively. Although spectrophotometric methods are considered as time and reagents consuming, this work is focused on its miniaturization, by reducing the volume of sample, as well as time and cost of analysis. In both methods, a micro-amount of sample is placed into a microplate reader with capacity for 96 samples, which can be analyzed in times ranging from 5 to 10 minutes. The proposed methods have been optimized using a Box-Behnken design of experiments. For Cu determination, concentration of phosphate buffer solution at pH 8.33, masking agents (ammonium fluoride, and sodium citrate) and dPKBH were optimized. For V analysis, sample pH=4.5 was obtained using acetic acid/sodium acetate buffer, and masking agents were ammonium fluoride and 1,2-cyclohexanediaminetetraacetic acid. Under optimum conditions both methods were applied to the analysis of certified reference materials TMDA-62 (lake water), LGC-6016 (estuarine water) and LGC-6019 (river water). In all cases results proved the accuracy of the method.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherELSEVIER Sci LTDes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceAnalytical Biochemistry 497:18-23.es_ES
dc.subjecttrace metalses_ES
dc.subjectmicroanalysises_ES
dc.subjectBox-Behnkenes_ES
dc.subjectCues_ES
dc.subjectVes_ES
dc.subjectdPKBHes_ES
dc.titleMiniaturized and direct spectrophotometric multi-sample analysis of trace metals in natural waterses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.type.hasVersionAMes_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional