JavaScript is disabled for your browser. Some features of this site may not work without it.

Improving thermal performance of a ventilated tiled roof by using phase change materials

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/33626

DOI: 10.1093/ijlct/ctad047

ISSN: 1748-1325

ISSN: 1748-1317

Files
OA_2024_0711.pdf (1.311Mb)
Statistics
View statistics
Metrics and citations
 
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
Bottarelli, Michele; Baccega, Eleonora; González Gallero, Francisco JavierAuthority UCA; Rodríguez Maestre, IsmaelAuthority UCA; Pei, Gang; Sue, Yuehong
Date
2023
Department
Física Aplicada; Máquinas y Motores Térmicos
Source
International Journal of Low-Carbon Technologies - 2023, Vol. 19 pp. 54-62
Abstract
The adoption of ventilated roofs and facades, as well as the integration of phase change materials (PCMs) in the building envelope, has proved to be effective as a passive cooling technique in reducing the solar heat gain through the building envelope during the summer period, therefore reducing the energy requirement for cooling. Even though much research focused on each of these strategies individually, their combination has not been deeply studied yet. Preliminary numerical studies were carried out on the application of PCMs on a pitched ventilated tiled roof, and the most effective position turned out to be the one suspended in the middle of the above sheathing ventilation (ASV) channel. Based on this conclusion and exploiting an existing mock-up facility, two equivalent pitched ventilated roofs with an air gap of 4 cm were built as coverage of two identical rooms, each one equipped with a fan coil, one with a 0.007-m PCM layer suspended in the middle of the ASV and the other one without. They were then tested under real conditions at the TekneHub Laboratory at the University of Ferrara. The behaviour of the two configurations were compared in terms of temperature, velocity of the air in the ASV, heat flux and energy requirement for cooling, which were monitored through T-type thermocouples, heat flow metre, anemometers and energy metres, respectively. The aim of the research was to validate the numerical results and confirm that the combination of the two strategies allows further improvement of roof performance.
Subjects
energy efficiency of buildings; passive cooling; phase change materials; ventilated roof
Collections
  • Artículos Científicos [11777]
  • Articulos Científicos Fis. Ap. [311]
  • Articulos Científicos Maq. Mot. Térm. [108]
Atribución 4.0 Internacional
This work is under a Creative Commons License Atribución 4.0 Internacional

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support