Show simple item record

dc.contributor.authorSantotoribio, Jose D.
dc.contributor.authorCorral Pérez, Juan 
dc.contributor.authorNuñez Jurado, David
dc.contributor.authorFatela Cantillo, Daniel
dc.contributor.authorGarcía de la Torre, Ángela
dc.contributor.authorOrantes Maroto, Gabirel
dc.contributor.authorDel Valle Vázquez, Luis
dc.contributor.authorDel Castillo Otero, Daniel
dc.contributor.authorMaira González, María Nieves 
dc.contributor.authorCobos Diaz, Andrés
dc.contributor.authorJuan M, Guerrero
dc.contributor.authorLópez Sáez, José Juan Bosco 
dc.contributor.otherDidáctica de la Educación Física, Plástica y Musicales_ES
dc.date.accessioned2025-01-10T13:56:51Z
dc.date.available2025-01-10T13:56:51Z
dc.date.issued2024
dc.identifier.issn1873-2933
dc.identifier.issn0009-9120
dc.identifier.urihttp://hdl.handle.net/10498/34336
dc.description.abstractIntroduction This multicenter study aimed to evaluate the Malignant Pleural Effusion Risk (MPER) diagnostic accuracy in distinguishing between benign and malign pleural effusion. Methods: MPER is based on pleural fluid Homocysteine (HCY) and carcinoembryonic antigen (CEA) that were measured using three different methods. MPER was calculated by assessing a previously published probabilistic model: Probability (%) = 100× (1 + e-z)-1, where Z = 0.5471 × [HCY] + 0.3846 × [CEA]–8.2671. Results A total of 301 patients were included (140 MPE). MPER demonstrated a high AUC (0.891), sensitivity (84.3 %), and specificity (80.7 %) with a cut-off > 35.3 %. Conclusions The MPER model demonstrated a high diagnostic accuracy supporting its use as a novel and powerful tool.Introduction This multicenter study aimed to evaluate the Malignant Pleural Effusion Risk (MPER) diagnostic accuracy in distinguishing between benign and malign pleural effusion. Methods: MPER is based on pleural fluid Homocysteine (HCY) and carcinoembryonic antigen (CEA) that were measured using three different methods. MPER was calculated by assessing a previously published probabilistic model: Probability (%) = 100× (1 + e-z)-1, where Z = 0.5471 × [HCY] + 0.3846 × [CEA]–8.2671. Results A total of 301 patients were included (140 MPE). MPER demonstrated a high AUC (0.891), sensitivity (84.3 %), and specificity (80.7 %) with a cut-off > 35.3 %. Conclusions The MPER model demonstrated a high diagnostic accuracy supporting its use as a novel and powerful tool.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.sourceClinical Biochemistry, Vol. 135, 2025es_ES
dc.titleMalignant Pleural Effusion Risk Based On A Novel Tool Using Homocysteine And Carcinoembryonic Antigen In Pleural Fluid: A Multicenter Studyes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsclosed accesses_ES
dc.identifier.doi10.1016/J.CLINBIOCHEM.2024.110841
dc.type.hasVersionVoRes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record