Show simple item record

dc.contributor.authorBlázquez Carmona, Pablo 
dc.contributor.authorSánchez Raya, Manuel
dc.contributor.authorMora Macías, Juan
dc.contributor.authorGómez Galán, Juan Antonio
dc.contributor.authorDomínguez, Jaime
dc.contributor.authorReina Romo, Esther
dc.contributor.otherIngeniería Mecánica y Diseño Industriales_ES
dc.date.accessioned2025-01-22T09:12:24Z
dc.date.available2025-01-22T09:12:24Z
dc.date.issued2020-08-15
dc.identifier.issn1424-8220
dc.identifier.urihttp://hdl.handle.net/10498/34637
dc.description.abstractFor the monitoring of bone regeneration processes, the instrumentation of the fixation is an increasingly common technique to indirectly measure the evolution of bone formation instead of ex vivo measurements or traditional in vivo techniques, such as X-ray or visual review. A versatile instrumented external fixator capable of adapting to multiple bone regeneration processes was designed, as well as a wireless acquisition system for the data collection. The design and implementation of the overall architecture of such a system is described in this work, including the hardware, firmware, and mechanical components. The measurements are conditioned and subsequently sent to a PC via wireless communication to be in vivo displayed and analyzed using a developed real-time monitoring application. Moreover, a model for the in vivo estimation of the bone callus stiffness from collected data was defined. This model was validated in vitro using elastic springs, reporting promising results with respect to previous equipment, with average errors and uncertainties below 6.7% and 14.04%. The devices were also validated in vivo performing a bone lengthening treatment on a sheep metatarsus. The resulting system allowed the in vivo mechanical characterization of the bone callus during experimentation, providing a low-cost, simple, and highly reliable solution.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMDPIes_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceSensors (Switzerland), Vol. 20, Núm. 16, 2020, pp. 1-23es_ES
dc.subjectexternal fixatores_ES
dc.subjectwireless acquisition systemes_ES
dc.subjectload sensores_ES
dc.subjectbone regenerationes_ES
dc.subjectcalibrationes_ES
dc.subjectcallus stiffnesses_ES
dc.titleReal-Time Wireless Platform for In Vivo Monitoring of Bone Regenerationes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.3390/s20164591
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2013-2016/DPI2017-82501-P/ES/REPARACION DE GRANDES DEFECTOS OSEOS: TRANSPORTE OSEO VERSUS ANDAMIAJES BIOIMPRIMIDOS PACIENTE PERSONALIZADOS/ es_ES
dc.relation.projectIDinfo:eu-repo/grantAgreement/AEI/Plan Estatal de Investigación Científica y Técnica y de Innovación 2017-2020/PGC2018-097257-B-C31/ES/CARACTERIZACION IN VITRO Y SIMULACION IN VITRO%2FIN VIVO DEL EFECTO DE LA HIPOXIA Y LA DOSIS FARMACOLOGICA EN EL CRECIMIENTO DEL GLIOBLASTOMA/ es_ES
dc.type.hasVersionVoRes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional