| dc.contributor.author | Sarrias-Mena, Raúl | |
| dc.contributor.author | Fernández-Ramírez, Luis M. | |
| dc.contributor.author | García-Vázquez, Carlos Andrés | |
| dc.contributor.author | Ugalde-Loo, Carlos E. | |
| dc.contributor.author | Jenkins, Nick | |
| dc.contributor.author | Jurado, Francisco | |
| dc.contributor.other | Ingeniería Eléctrica | es_ES |
| dc.contributor.other | Ingeniería en Automática, Electrónica, Arquitectura y Redes de Computadores | es_ES |
| dc.date.accessioned | 2025-01-29T09:07:40Z | |
| dc.date.available | 2025-01-29T09:07:40Z | |
| dc.date.issued | 2016-07-18 | |
| dc.identifier.isbn | 978-1-4673-8463-6 | |
| dc.identifier.uri | http://hdl.handle.net/10498/34998 | |
| dc.description.abstract | Electric power systems will need to accommodate large amounts of renewables and a growing number of DC loads with reduced costs and losses. Medium-voltage DC distribution lines can play a key role. Moreover, a higher availability and reliability of the power supply can be achieved with energy storage systems (ESSs). In this paper, a hybrid configuration merging both concepts is evaluated. A medium-voltage DC distribution system with an integrated ESS has been proposed, modelled, and simulated. Voltage source converters have been used for the AC/DC conversions. The ESS is connected to the DC bus through a dual active bridge enabling bidirectional power flow while covering a large voltage gap. The controllers for all converters and a supervisory control scheme have been implemented. Simulations show the capability of the hybrid configuration to fulfill variable grid demand regardless of the wind power generation, thus transforming a fluctuating source into a dispatchable supply. | es_ES |
| dc.format | application/pdf | es_ES |
| dc.language.iso | eng | es_ES |
| dc.publisher | IEEE | es_ES |
| dc.rights | Attribution-NonCommercial-NoDerivatives 4.0 Internacional | * |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | * |
| dc.source | 2016 IEEE International Energy Conference, ENERGYCON 2016 | es_ES |
| dc.subject | Power conversion | es_ES |
| dc.subject | Wind farms | es_ES |
| dc.subject | Voltage control | es_ES |
| dc.subject | Energy storage | es_ES |
| dc.subject | Wind power generation | es_ES |
| dc.subject | Medium voltage | es_ES |
| dc.title | Modelling and control of a medium-voltage DC distribution system with energy storage | es_ES |
| dc.type | conference output | es_ES |
| dc.rights.accessRights | open access | es_ES |
| dc.identifier.doi | https://doi.org/10.1109/ENERGYCON.2016.7513990 | |
| dc.identifier.doi | 10.1109/ENERGYCON.2016.7513990 | |
| dc.relation.projectID | info:eu-repo/grantAgreement/MINECO//ENE2013-46205-C5-1-R/ES/MVDC EN EL TRANSPORTE ELECTRICO/ | es_ES |
| dc.type.hasVersion | AM | es_ES |