Show simple item record

dc.contributor.authorRomero Martínez, Leonardo 
dc.contributor.authorVan Slooten, Cees
dc.contributor.authorVan Harten, Michiel
dc.contributor.authorNebot Sanz, Enrique 
dc.contributor.authorPeperzak, Louis
dc.contributor.otherBiologíaes_ES
dc.contributor.otherTecnologías del Medio Ambientees_ES
dc.date.accessioned2025-05-27T09:45:05Z
dc.date.available2025-05-27T09:45:05Z
dc.date.issued2024
dc.identifier.issn1879-3363
dc.identifier.issn0025-326X
dc.identifier.urihttp://hdl.handle.net/10498/36378
dc.description.abstractCompliance Monitoring Devices (CMDs) are instruments indicating if the 10–50 μ m organism abundance in ballast water complies with the International Maritime Organizations' discharge standard. For that, they trade the presumed accuracy of detailed methods for speed and simplicity. In an experiment using UV-treated water, four CMDs were compared, using a Cohen's kappa analysis (ISO 3725), with two detailed methods: Fluorescence Microscopy (FM) and the Most Probable Number (MPN). Of two CMDs, BallastWISE and B-QUA ATP, the standard (non)-compliance limits were adapted. Correlated to FM (non)-compliance results, ranking resulted in: 1) BallastWISE, 2) MPN, 3) Ballast-Check-2 and 4) WALZ-PAM. The ATP method had too few data for this ranking. MPN proved problematic: the abundance of 10–50 μ m organism decreased while that <10 m organisms increased. It is concluded that in case of UV-treatment, the outcome of CMD-validations will depend on the detailed method, the CMD instrument, and the (non)-compliance limits chosen.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceMarine Pollution Bulletin - 2024, Vol. 209 pp. 1-12es_ES
dc.subjectBallast wateres_ES
dc.subjectUV-treatmentes_ES
dc.subjectCMD-validationes_ES
dc.subjectCohen's kappaes_ES
dc.titleComparative assessment of four ballast water compliance monitoring devices with natural UV-treated water using IMO's monitoring approacheses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/J.MARPOLBUL.2024.117193
dc.relation.projectIDinfo:eu-repo/grantAgreement/Junta de Andalucía//FEDER-UCA18-105151es_ES
dc.type.hasVersionVoRes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional