Mostrar el registro sencillo del ítem

dc.contributor.authorPalacio, Montse
dc.contributor.authorBonet Carne, Elisenda
dc.contributor.authorCobo, Teresa
dc.contributor.authorPérez Moreno, Álvaro
dc.contributor.authorSabrià, Joan
dc.contributor.authorRichter, Jute
dc.contributor.authorKacerovsky, Marian
dc.contributor.authorJacobsson, Bo
dc.contributor.authorGarcía Posada, Raúl A.
dc.contributor.authorBugatto González, Fernando 
dc.contributor.authorQuintero Prado, Rocío 
dc.contributor.authorBenavente Fernández, Isabel 
dc.contributor.otherMaterno-Infantil y Radiologíaes_ES
dc.date.accessioned2025-07-14T09:53:31Z
dc.date.available2025-07-14T09:53:31Z
dc.date.issued2017
dc.identifier.issn1097-6868
dc.identifier.issn0002-9378
dc.identifier.urihttp://hdl.handle.net/10498/36716
dc.description.abstractBackground Prediction of neonatal respiratory morbidity may be useful to plan delivery in complicated pregnancies. The limited predictive performance of the current diagnostic tests together with the risks of an invasive procedure restricts the use of fetal lung maturity assessment. Objective The objective of the study was to evaluate the performance of quantitative ultrasound texture analysis of the fetal lung (quantusFLM) to predict neonatal respiratory morbidity in preterm and early-term (<39.0 weeks) deliveries. Study Design This was a prospective multicenter study conducted in 20 centers worldwide. Fetal lung ultrasound images were obtained at 25.0–38.6 weeks of gestation within 48 hours of delivery, stored in Digital Imaging and Communication in Medicine format, and analyzed with quantusFLM. Physicians were blinded to the analysis. At delivery, perinatal outcomes and the occurrence of neonatal respiratory morbidity, defined as either respiratory distress syndrome or transient tachypnea of the newborn, were registered. The performance of the ultrasound texture analysis test to predict neonatal respiratory morbidity was evaluated. Results A total of 883 images were collected, but 17.3% were discarded because of poor image quality or exclusion criteria, leaving 730 observations for the final analysis. The prevalence of neonatal respiratory morbidity was 13.8% (101 of 730). The quantusFLM predicted neonatal respiratory morbidity with a sensitivity, specificity, positive and negative predictive values of 74.3% (75 of 101), 88.6% (557 of 629), 51.0% (75 of 147), and 95.5% (557 of 583), respectively. Accuracy was 86.5% (632 of 730) and positive and negative likelihood ratios were 6.5 and 0.3, respectively. Conclusion The quantusFLM predicted neonatal respiratory morbidity with an accuracy similar to that previously reported for other tests with the advantage of being a noninvasive technique.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherMosby Inc.es_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/*
dc.sourceAmerican Journal of Obstetrics and Gynecology - 2017, Vol. 217 n. 2 pp. 196.e1-196.e14es_ES
dc.subjectamniocentesises_ES
dc.subjectamniotic fluid analysises_ES
dc.subjectbiomarkeres_ES
dc.subjectcomputational methodses_ES
dc.subjectdiagnostic indiceses_ES
dc.subjectfetal lung maturityes_ES
dc.subjectneonatal respiratory morbidityes_ES
dc.subjectpredictive valueses_ES
dc.subjectquantitative texture analysises_ES
dc.subjectrespiratory distress syndromees_ES
dc.subjectsonographyes_ES
dc.subjecttransient tachypneaes_ES
dc.subjectultrasoundes_ES
dc.titlePrediction of neonatal respiratory morbidity by quantitative ultrasound lung texture analysis: a multicenter studyes_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/J.AJOG.2017.03.016
dc.type.hasVersionVoRes_ES


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
Esta obra está bajo una Licencia Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 Internacional