Study of ground motion signal reduction for the optimisation of computation time in dynamic nonlinear analysis

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/37002

DOI: 10.1016/J.ISTRUC.2025.108291

ISSN: 2352-0124

Files
OA_2025_0237.pdf (17.50Mb)
Statistics
View statistics
Metrics and citations
 
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
Requena García de la Cruz, María VictoriaAuthority UCA; de-Miguel-Rodriguez, J.; Romero Sánchez, EmilioAuthority UCA; Morales Esteban, A.
Date
2025
Department
Ingeniería Mecánica y Diseño Industrial
Source
Structures - 2025, Vol. 72
Abstract
Nonlinear dynamic analyses are required to account for the structural performance of mid- to high-rise buildings and complex structures. Generally, time history analyses are carried out considering several ground motions for a certain seismic action. These analyses are often very time-consuming, mainly because of the high resolution of the ground motion signal. Therefore, performing these calculations based on lower resolution accelerograms can be very useful, especially when dealing with large sets of buildings (e.g., seismic vulnerability studies on an urban scale). In this paper, two methods for signal reduction are tested against each other: i) an open-source Fourier-based resampling implementation; and, ii) a simple reduction algorithm that preserves both the highest and lowest peaks of the signal. The experiments compare the two methods at several levels of resolution reduction and for three different accelerograms. The influence of amplitude scaling on important earthquake demand parameters (EDPs), namely, the peak floor displacements and accelerations have been studied for three reinforced concrete case study buildings modelled in OpenSees: low- (5-storey), mid- (8-storey) and high-rise (11-storey). The results allow establishing a set of criteria to choose the appropriate reduction method and level. This depends on the balance desired of computation time versus calculation accuracy. Real accelerograms without baseline corrections have been for the tests. The simple reduction algorithm method appears to capture better the accelerograms by avoiding excessive interpolation. This results in peaks and areas closer to the original signal. However, it presents greater variability in energy preservation, introducing large abrupt changes in acceleration. These large fluctuations have led to inducing significantly larger displacements in OpenSees, causing greater structural damage. The Fourier method led to better and consistent results than the reduction algorithm proposed. Resolution 50 provided a reduction in time of up to 30 % and an error margin of the engineering demand parameters of around ± 15 %.
Subjects
Ground motion; Nonlinear dynamic analysis; OpenSees; Optimisation; Seismic assessment; Signal reduction
Collections
  • Artículos Científicos [11954]
  • Articulos Científicos Ing. Mec. [324]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support