• español
    • English
  • Login
  • English 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Communities and Collections
View Item 
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Exploring a new approach to ancient Qanat techniques using earth-air and water-air heat exchangers for efficient natural cooling

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/38706

DOI: 10.1016/J.ENCONMAN.2025.120066

ISSN: 0196-8904

Files
OA_2025_0659.pdf (13.94Mb)
Statistics
View statistics
Metrics and citations
 
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
Montero Gutiérrez, Paz; Sanchez Ramos, José; Castro Medina, DanielAuthority UCA; Palomo Amores, Teresa Rocío
Date
2025
Department
Máquinas y Motores Térmicos
Source
Energy Conversion and Management - 2025, Vol. 341, artículo n. 120066
Abstract
The growing demand for sustainable climate adaptation in cities has intensified interest in passive, energy-efficient cooling systems, especially for semi-open public spaces where conventional air-conditioning solutions are often inefficient. This study proposes a novel reinterpretation of the Persian Qanat system, integrating it with contemporary engineering through Earth-Air and Water-Air Heat Exchangers to create nature-based infrastructure for urban cooling. The experimental set-up is installed at full scale in a public space and includes buried ducts interacting with the soil and submerged ducts connected to a water reservoir named Qanat. The system operates in two phases: daytime cooling by passive heat exchange and nighttime regeneration using evaporative and radiative cooling to restore thermal capacity. Performance was assessed through continuous environmental monitoring, including air, soil and water temperatures, and cooling energy calculations. The results indicate air temperature reductions of up to 8 °C between the inlet and outlet of the ducts during the hottest hours of the day. At night, evaporative regeneration reduced the soil temperature to 23 °C, improving the cooling potential for the following day. The energy analysis showed daily cooling values reaching up to 19 kWh. These findings confirm the potential of the system as a scalable and sustainable climate solution, enhancing thermal comfort in urban environments while recovering ancestral techniques adapted through modern design.
Subjects
Earth-air heat exchanger; Natural resources; Qanat; Soil regeneration; Urban climate shelter; Water-air heat exchanger
Collections
  • Artículos Científicos [11954]
  • Articulos Científicos Maq. Mot. Térm. [108]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support