dc.description.abstractRising temperatures pose a significant challenge for obsolete buildings, which constitute up to 30% of Europe’s building stock. Current energy renovation policies, while effective for decarbonization, exhibit a critical ’winter bias.’ By prioritizing thermal insulation without mandating adaptive cooling strategies, these regulations risk locking social housing stock into a trajectory of structural overheating, exacerbating health risks in increasingly warm climates. Moreover, in situations where households cannot afford or use air-conditioning systems and high temperatures are frequent, building retrofits should prioritise both reducing winter heat losses and passively lowering indoor temperatures during the warmer season. This research, therefore, evaluates the effectiveness of these standards under climate change conditions by projecting towards a 2080-time horizon, analysing an archetypal mid-20th century social housing case, which operates passively like many of those in temperate and warm climates. Through an assessment with a prior diagnosis based on climate evolution scenarios, a thermo- energy analysis focused on passive comfort is carried out, analysing all representative dwellings of a whole neighbourhood. The results show that, while the initial retrofit based solely on current standards results in improvements in the cold season, summer conditions worsen and there is limited improvement on the annual average. As an alternative, this study proposes an adapted improvement based on intelligent ventilation control. This could be easily implemented in refurbished buildings, ensuring thermal comfort for more than 90% of the hours of the year without relying on active climate control systems.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherElsevieres_ES
dc.rightsAttribution-NonCommercial-NoDerivatives 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/es_ES
dc.sourceEnergy and Buildings - 2026, Vol. 365, 117673es_ES
dc.subjectBuilding refurbishmentes_ES
dc.subjectIndoor energy performancees_ES
dc.subjectPassive thermal comfortes_ES
dc.subjectClimate changees_ES
dc.subjectHeat riskes_ES
dc.subjectNatural ventilationes_ES
dc.subjectLow-income dwellingses_ES
dc.titleHow effective are regulation-based passive retrofits in adapting social housing to overheating scenarios?es_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/J.ENBUILD.2026.117673
dc.relation.projectIDPID2021-124539OB-I00es_ES
dc.relation.projectIDPID2024-155805OB-C21es_ES
dc.relation.projectIDFPU21/02458es_ES
dc.relation.projectIDJDC2023-050880-Ies_ES
dc.relation.projectIDJDC2023-050478-Ies_ES
dc.type.hasVersionVoRes_ES


Files in this item

This item appears in the following Collection(s)

Show simple item record

Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional