dc.description.abstractWith the reagents (0.05M copper nitrate solution, 0.05M zinc nitrate solution) and material (glassware, potentiometer, electric wire) availabe in the laboratory, the user must set up the Daniell cell. Different configurations can be possible if the half cells are filled with either electrolyte solution. The cell connections to the measuring device can also be changed. In all instances, an explanation of the set up cell is obtained as well as of the measured potential difference.en_US
dc.formatapplication/vnd.adobe.flash-movie
dc.language.isoengen_US
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectgalvanic cell
dc.subjectDaniell cell
dc.subjectelectrochemistry
dc.subjectCu(II)/Cu redox couple
dc.subjectZn(II)/Zn redox couple
dc.titleGalvanic cells: setting up the Daniell cell.en_US