• español
    • English
  • Login
  • English 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Communities and Collections
View Item 
  •   RODIN Home
  • Departamentos
  • Química Analítica
  • Material Docente Quim. Ana.
  • View Item
  •   RODIN Home
  • Departamentos
  • Química Analítica
  • Material Docente Quim. Ana.
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Volumetric titrations: calculating the titration percent relative error.

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/7043

Files
titration_error.swf (138.3Kb)
Statistics
View statistics
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
Milla González, Miguel
Date
2008-09-30
Abstract
The difference between the found value and the real value is known as the absolute error. When applied to a titration, the absolute error comes from the difference between the real amount of analyte present in the sample and the amount of it calculated from the titration data (namely, the titrant volume at the endpoint and the titrant molarity). In most cases, the true amount of analyte is a statistical problem. In titrations, the relative error is minimized when endpoint and stoichiometric point (both in terms of consumed volume of titrant) are very close to each other. More widely used is the percent relative error (PRE). In this exercise, a volumetric titration is carried out using a visual indicator to determine the endpoint. The analyst must stop titration just at the moment the titrated solution changes color. From the titrant volume required and data about the analyzed problem, the percent relative error should be calculated. When overtitration occurs, the error value becomes significant.
Subjects
volumetric analysis; titration; titration absolute error; titration percent relative
Collections
  • Material Docente Quim. Ana. [533]
  • Objetos de Aprendizaje [1316]

Related items

Showing items related by title, author, creator and subject.

  • Making pH calculations in the titration of strong protolytes 

    Milla González, Miguel (2013-10-21)
  • Iodometric titration of a Cu(II) solution. An interactive exercise. 

    Milla González, Miguel (2013-05-07)
  • Calculations with weak protolytes: titration of acetic acid with NaOH solution. 

    Milla González, Miguel (2013-10-28)

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support