RT journal article T1 The frequency spectrum of the acoustic environment in a neonatal intensive care unit A1 Rodríguez Montaño, Víctor Manuel A1 Beira Jiménez, Juan Luis A1 Fernández Zacarías, Francisco A1 Cueto Ancela, José Luis A1 Puyana Romero, Virginia A1 Hernández Molina, Ricardo A2 Ciencias y Técnicas de la Navegación y Construcciones Navales A2 Ingeniería Eléctrica A2 Ingeniería Mecánica y Diseño Industrial A2 Máquinas y Motores Térmicos K1 Hearing K1 Intensive care units K1 Neonatal K1 Newborn K1 Noise K1 Pediatrics AB Objectives: The acoustic frequencies present in an incubator are within the hearing range of a newborn; this requires adapting the environment so that the noise inside the incubator is more compatible with that range and facilitates proper hearing development. The objective of this study is to make a comparison, in thirds of an octave (frequency analysis), of the noise present in the NICU room and the interior space of the incubator, analyzing the ambient acoustic quality perceived by the newborn. Methods: The experiment carried out in this work consisted of two series of measurements of noise levels in the NICU of the “Puerta del Mar” University Hospital (Cádiz, Spain) and two selected incubators in the room. A third-octave frequency band analysis was performed within the audible field (20 Hz/20 kHz). Data were recorded at 1 s intervals for more than 24 h (3600 registers de 1 s.) Results and conclusions: One may wonder if noise levels inside incubators affect newborns. Based on existing references, the answer is probably “yes”, since the frequencies present inside an incubator are within the audible range of a newborn. According to the consulted bibliography, the audible range of neonates is between 400 Hz and 4 kHz. In this work, the acoustic measurements carried out in the NICU made it possible to evaluate the noise levels in the room and inside the incubators. According to the results, the indicator used LAeq, 1 h, should be complemented with a study in 1/3 octave bands (frequency analysis) to determine the acoustic quality and hearing protection of neonates PB Elsevier SN 1018-3647 YR 2023 FD 2023-02-28 LK http://hdl.handle.net/10498/28824 UL http://hdl.handle.net/10498/28824 LA eng NO The authors are grateful to the NICU staff of the “Puerta del Mar” University Hospital (Cadiz, Spain), for their help in the development of this work. As well as the University of Cádiz for the concession of the Project within the framework of the “Program for the promotion and promotion of research and transfer at the University of Cádiz 2016-2017”, which has allowed the realization of this work. DS Repositorio Institucional de la Universidad de Cádiz RD 10-may-2026