RT journal article T1 Low power static-heating start-up procedure for supercritical water oxidation plants A1 Benjumea Triguero, José Manuel A1 Sánchez Oneto, Jezabel A1 Portela Miguélez, Juan Ramón A1 Jiménez-Espadafor Aguilar, Francisco José A1 Martínez de la Ossa Fernández, Enrique José A2 Ingeniería Química y Tecnología de Alimentos K1 Supercritical water oxidation K1 Pilot plant K1 Start-up K1 Static heating K1 Experimental sets K1 Energy optimization AB One of the factors against the upscaling of SCW plants is the enormous amount of energy demanded during the start-up phase to reach the stationary state and the autothermic operation phase.This work proposes a new strategy with a lower energy cost and, consequently, with a smaller initial investment. It consists on statically heating up different sections in an SCWO plant by means of electric heaters distributed throughout the plant. A constant temperature of 400 °C can be reached in a plant containing a mixture of water and ethanol at near critical pressure. Then, when the feed and the oxidant are pumped, the oxidation reactions starts. Such reaction, in turn, releases the heat required for autothermal operation. The experiments that have been carried out have confirmed that the Low Power Static-heating Start-up Procedure (LPSSP) proposed would mean a saving of 46.4% in power consumption when compared to a conventional startup procedure. PB ELSEVIER B. V. SN 0896-8446 YR 2018 FD 2018-01-31 LK http://hdl.handle.net/10498/31015 UL http://hdl.handle.net/10498/31015 LA eng NO Junta de Andalucía, proyecto P11-RNM-70-48CeiA3 DS Repositorio Institucional de la Universidad de Cádiz RD 11-nov-2026