RT journal article T1 Microplastics in drinking water. Efficiency of treatment and distribution of a drinking water cycle A1 Rodríguez Barroso, María del Rocío A1 Cruceira Fernández de Arjona, Álvaro A1 Coello Oviedo, María Dolores A1 Quiroga Alonso, José María A1 Egea-Corbacho Lopera, Agata A2 Tecnologías del Medio Ambiente AB It is known that there are many sources of microplastics (MPs) contamination in reservoir water catchment areas.In addition, sampling, analysis, and determination techniques are not standardized, making not only samplingcomplicated, but also the comparison and extrapolation of the data obtained with other studies. This is furthermagnified in the determination in drinking water matrices. Furthermore, among the legislative aspects, in-troduces for the first time at the watch list about pollutant to be consider. Therefore, the objective of this study isto know the presence of MPs in the drinking water distribution cycle (natural reservoir (S1), outflow of thedrinking water treatment plant (S2), city’s reservoir (S3) and a municipal control point of the supply network(S4)), for this purpose a method for the analysis and determination of MPs in drinking water is set up andproposed. In order to carry out the study, several samples were taken at different points of the drinking waterdistribution pathway. Based on the shape of the particles, the result shows the predominance of fragments overfibers and bulk. A difference is observed between these forms between incoming (S1) and outgoing samples (S2to S4); while in S1 it seems that fiber predominates over bulk, in S2 bulk predominate and in less concentrationfibers. In S3 and S4 the tendency is similar to the S2, there is a predominance of fragment followed by bulk andfinally fibers. Regarding the abundance of these polymers, it was 1550 ± 891 MP/m3 at S1, 115 ± 35 MP/m3 atS2, 435 ± 120 MP/m3 at S3 and 450 ± 221 MP/m3 in S4. These results show that is able to establish an averageefficiency of the 92 ± 2 % removal of MPs in the purification processes. Likewise, regarding the typology ofpolymers, the most representative were PTFE, PE and PS. The amount of MPs is higher at the DWTP inlet than atthe outflow, indicating that the treatment may reduce them, even if not specifically designed to do so. This study,conducted in a DWTP with conventional treatment, suggests these findings could apply to other similar plants.An increase in MPs has been noted from the DWTP outlet to the storage tanks and the city’s distribution network,possibly due to material carryover and pipe wear PB Elsevier YR 2025 FD 2025 LK http://hdl.handle.net/10498/36261 UL http://hdl.handle.net/10498/36261 LA eng DS Repositorio Institucional de la Universidad de Cádiz RD 20-nov-2026