RT journal article T1 Validity and reliability of V˙O2max determination immediately after a maximal fat oxidation assessment in pre-diabetes/type 2 Diabetes Mellitus population A1 Marín Galindo, Alberto A1 Opazo Díaz, Edgardo A1 Ramírez Jiménez, Miguel A1 Montes de Oca García, Adrian A1 Corral Pérez, Juan A1 Pérez Pérez, Alejandro A1 Casals Vázquez, Cristina A1 Ponce González, Jesús Gustavo A2 Didáctica de la Educación FísicaPlástica y Musical K1 Validation K1 Cardiorespiratory fitness K1 FatMax K1 Metabolic flexibility K1 Exercise tests K1 Exercise physiology AB Background: Measuring maximal fat oxidation (MFO) and maximal oxygen consumption (V_ O2max) typically requires two separate days, which can be time-consuming. This study aimed to assess the validity and reliability of asingle-day test for measuring MFO and V_ O2max in individuals with pre-diabetes/type 2 diabetes (T2DM).Methods: Twenty adults with pre-diabetes/T2DM (10 women; [53.1 8.8] years) participated in this crosssectional study. Participants underwent a single-day MFO- V_ O2max protocol, followed by the traditional V_ O2maxtest on a cycle ergometer 4–7 days later, with both assessments performed using indirect calorimetry. The singleday test commenced with the MFO test, involving 15 W per 3 min increments until the respiratory exchange ratereached 1.0. After a 5-minute (min) rest, the V_ O2max test was conducted, starting at the last load and increasing by15 W⋅min-1 until voluntary exhaustion. The traditional V_ O2max test involved a 15 W⋅min-1n incremental protocoluntil voluntary exhaustion, followed by a verification test at 110% of the previous maximum load.Results: No significant differences were observed between MFO-V_ O2max and traditional V_ O2max protocol in V_ O2maxvalues ([2 099.4 534.1] ml⋅min-1 vs. [2 119.1 548.3] ml⋅min-1, p ¼ 0.715) or heart rate ([163.2 18.2] beat/min vs. [164.5 16.1] beat/min, p ¼ 0.485). The MFO-V_ O2max protocol test demonstrated excellent reliability(intraclass correlation coefficient ¼ 0.957), limits of agreement ranging from 300.06 ml⋅min-1 to 306.77 ml⋅min-1,and the standard error of measurement was 181.67 ml⋅min-1.Conclusions: Therefore, the single-day test is a valid and reliable method for assessing both MFO and V_ O2max inmen and women with pre-diabetes/T2DM. With a mean total duration of (34 8) min, this test enhances clinicalapplicability by significantly reducing the time and cost associated with traditional assessments. PB KeAi SN 2666-3376 YR 2025 FD 2025 LK http://hdl.handle.net/10498/36492 UL http://hdl.handle.net/10498/36492 LA eng DS Repositorio Institucional de la Universidad de Cádiz RD 11-nov-2026