TY - GEN AU - García López, María del Carmen AU - Álvarez Tey, Germán A4 - Ingeniería Eléctrica PY - 2022 SN - 1424-8220 UR - http://hdl.handle.net/10498/27955 AB - Faults in photovoltaic modules in operation can lead to power losses. By determining the module surface temperature, hot spots that can potentially cause this power loss can be detected. Temperature measurement by radiation allows a complete,... LA - eng PB - MDPI KW - PV temperature measurement KW - degradation KW - uncertainty KW - accurate and precision analysis TI - Evaluation of the Uncertainty of Surface Temperature Measurements in Photovoltaic Modules in Outdoor Operation DO - 10.3390/s22155685 ER -