Automated Home Oxygen Delivery for Patients with COPD and Respiratory Failure: A New Approach

Ficheros
Estadísticas
Métricas y Citas
Metadatos
Mostrar el registro completo del ítemFecha
2020-02Departamento/s
Ingeniería en Automática, Electrónica, Arquitectura y Redes de ComputadoresFuente
Sensors 2020, 20(4), 1178Resumen
Long-term oxygen therapy (LTOT) has become standard care for the treatment of patients with chronic obstructive pulmonary disease (COPD) and other severe hypoxemic lung diseases. The use of new portable O-2 concentrators (POC) in LTOT is being expanded. However, the issue of oxygen titration is not always properly addressed, since POCs rely on proper use by patients. The robustness of algorithms and the limited reliability of current oximetry sensors are hindering the effectiveness of new approaches to closed-loop POCs based on the feedback of blood oxygen saturation. In this study, a novel intelligent portable oxygen concentrator (iPOC) is described. The presented iPOC is capable of adjusting the O-2 flow automatically by real-time classifying the intensity of a patient's physical activity (PA). It was designed with a group of patients with COPD and stable chronic respiratory failure. The technical pilot test showed a weighted accuracy of 91.1% in updating the O-2 flow automatically according to medical prescriptions, and a general improvement in oxygenation compared to conventional POCs. In addition, the usability achieved was high, which indicated a significant degree of user satisfaction. This iPOC may have important benefits, including improved oxygenation, increased compliance with therapy recommendations, and the promotion of PA.
Materias
COPD; oxygen concentrator; oxygen therapy; automatic oxygen concentrator; physical activity; machine learning; respiratory medicine; portable oxygen concentrator; oxygen deliveryColecciones
- Artículos Científicos [12014]
- Articulos Científicos Ing. Sis. Aut. [193]
- Artículos Científicos INIBICA [1093]
Ítems relacionados
Mostrando ítems relacionados por Título, autor o materia.
-
The impact of Mn nonstoichiometry on the oxygen mass transport properties of La0.8Sr0.2MnyO3±δ thin films
Chiabrera, Francesco M; Baiutti, Federico; Börgers, Jacqueline M; Harrington, George F; Yedra, Lluís; Liedke, Maciej O; Kler, Joe; Nandi, Pranjal; Sirvent, Juan de Dios; Santiso, Jose; López Haro, Miguel
; Calvino Gámez, José Juan
; Estradé, Sonia; Butterling, Maik; Wagner, Andreas; Peiró, Francesca; De Souza, Roger A; Tarancón, Albert; kler (IOP Publishing Ltd, 2022-10)





