• español
    • English
  • Login
  • English 
    • español
    • English

UniversidaddeCádiz

Área de Biblioteca, Archivo y Publicaciones
Communities and Collections
View Item 
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
  •   RODIN Home
  • Producción Científica
  • Artículos Científicos
  • View Item
JavaScript is disabled for your browser. Some features of this site may not work without it.

Development and validation of a sampling and analysis method to determine biogenic sulfur in a desulfurization bioreactor by gas chromatography coupled with a pulsed flame photometric detector (GC-PFPD).

Thumbnail
Identificadores

URI: http://hdl.handle.net/10498/25885

DOI: 10.1016/j.jhazmat.2021.127667

ISSN: 1873-3336

Files
APC_2021_068.pdf (1.422Mb)
Statistics
View statistics
Metrics and citations
 
Share
Export
Export reference to MendeleyRefworksEndNoteBibTexRIS
Metadata
Show full item record
Author/s
Torres Herrera, SandraAuthority UCA; González Cortés, José JoaquínAuthority UCA; Almengló Cordero, FernandoAuthority UCA; Ramírez Muñoz, MartínAuthority UCA; Cantero Moreno, DomingoAuthority UCA
Date
2022-02
Department
Ingeniería Química y Tecnología de Alimentos
Source
Journal of Hazardous Materials 424 (2022) 127667
Abstract
Suspended biomass bioreactors can be operated to remove H2S from biogas under anoxic conditions and produce elemental sulfur, the commercial value of which has been demonstrated. In the present paper, a novel methodology comprising the optimization of a determination method performed in a gas chromatograph equipped with a pulsed flame photometric detector (GC-PFPD), combined with a simple preparation based on filtration and extraction with toluene, is proposed. The injector temperature and carrier gas flow rate (QHe) values were optimized using a response surface methodology based on a face-centred composite central design. This optimization revealed that the optimum conditions were an injector temperature and carrier gas flow rate of 222°C and 7mLmin-1, respectively. The chromatographic method shows an analysis time of 48min, a detection limit of more than 5.9mgL-1, a relative standard deviation of less than 3.71%, and a sulfur recovery percentage of more than 98%. These values provide excellent linearity and a reasonable concentration range (10-200mgL-1). Finally, a measurement error of 4.45% was obtained when using the present method in a selectivity test. Copyright © 2021 The Authors. Published by Elsevier B.V. All rights reserved.
Subjects
Biogenic sulfur; GC-PFPD; Toluene; Filtration; Response surface methodology (RSM)
Collections
  • Artículos Científicos [11973]
  • Articulos Científicos Ing. Quim. [313]
  • Artículos Científicos IVAGRO [733]
Attribution-NonCommercial-NoDerivatives 4.0 Internacional
This work is under a Creative Commons License Attribution-NonCommercial-NoDerivatives 4.0 Internacional

Browse

All of RODINCommunities and CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

My Account

LoginRegister

Statistics

View Usage Statistics

Información adicional

AboutDeposit in RODINPoliciesGuidelinesRightsLinksStatisticsNewsFrequently Asked Questions

RODIN is available through

OpenAIREOAIsterRecolectaHispanaEuropeanaBaseDARTOATDGoogle Academic

Related links

Sherpa/RomeoDulcineaROAROpenDOARCreative CommonsORCID

RODIN está gestionado por el Área de Biblioteca, Archivo y Publicaciones de la Universidad de Cádiz

Contact informationSuggestionsUser Support