Solar disinfection - An appropriate water treatment method to inactivate faecal bacteria in cold climates

Identificadores
URI: http://hdl.handle.net/10498/27191
DOI: 10.1016/j.scitotenv.2022.154086
ISSN: 1879-1026
Files
Statistics
Metrics and citations
Metadata
Show full item recordDate
2022-06Department
Tecnologías del Medio AmbienteSource
Science of the Total Environment, Vol. 827Abstract
Solar disinfection (SODIS) is an inexpensive drinking water treatment method applied in tropical and sub-tropical lowincome countries. However, it has been unclear whether it functions adequately also in colder climates. To investigate this issue, SODIS experiments were performed in the humid continental climate of Finland by exposing faecally contaminated drinking water to natural solar radiation at different water temperatures (8-23 degrees C) and UV intensities (12-19 W/m(2)) in polyethylene (PE) bags. To establish an adequate benchmark, SODIS experiments with the same experimental design were additionally conducted in the Mediterranean climate of Spain in typical conditions of SODIS application (similar to 39 degrees C and 42 W/m(2)).
Out of all experiments, the highest coliform and enterococci inactivation efficiencies in terms of lowest required doses for 4-log disinfection (25 Wh/m(2) and 60 Wh/m(2), respectively) were obtained in humid continental climate at the lowest studied mean water temperature (8-11 degrees C). Despite the low mean UV irradiance (-19 Wh/m(2)), 4-log disinfection of coliforms and enterococci were also reached fast in these conditions (1 h 27 min and 3 h 18 min, respectively). Overall, the doses required for disinfection increased as the water temperatures and UV intensities of the experiments rose. Disinfection of 4-logs (> 99.99%) of both bacteria was reached in all SODIS experiments within 6 h, suggesting SODIS could be a sufficient household water treatment method also in colder climates, unlike previously thought.
The effects of different water temperatures on bacterial inactivation were also tested in the absence of sunlight. Together the obtained results indicate that while water temperatures below or close to the optima of coliforms and enterococci (similar to 10 degrees C) alone do not cause inactivation, these temperatures may enhance SODIS performance. This phenomenon is attributed to slower bacterial metabolism and hence slower photorepair induced by the low water temperature.
Subjects
SODIS; Household water treatment and safe storage; (HWTS); Low temperature disinfection; Frugal technologies; Emergency waterCollections