Show simple item record

dc.contributor.authorJuvakoski, Anni
dc.contributor.authorSinghal, Gaurav
dc.contributor.authorManzano Quiñones, Manuel Alejandro 
dc.contributor.authorMoriñigo, Miguel Ángel
dc.contributor.authorVahala, Riku
dc.contributor.authorLevchuk, Irina
dc.contributor.otherTecnologías del Medio Ambientees_ES
dc.date.accessioned2022-07-15T11:37:34Z
dc.date.available2022-07-15T11:37:34Z
dc.date.issued2022-06
dc.identifier.issn1879-1026
dc.identifier.urihttp://hdl.handle.net/10498/27191
dc.description.abstractSolar disinfection (SODIS) is an inexpensive drinking water treatment method applied in tropical and sub-tropical lowincome countries. However, it has been unclear whether it functions adequately also in colder climates. To investigate this issue, SODIS experiments were performed in the humid continental climate of Finland by exposing faecally contaminated drinking water to natural solar radiation at different water temperatures (8-23 degrees C) and UV intensities (12-19 W/m(2)) in polyethylene (PE) bags. To establish an adequate benchmark, SODIS experiments with the same experimental design were additionally conducted in the Mediterranean climate of Spain in typical conditions of SODIS application (similar to 39 degrees C and 42 W/m(2)). Out of all experiments, the highest coliform and enterococci inactivation efficiencies in terms of lowest required doses for 4-log disinfection (25 Wh/m(2) and 60 Wh/m(2), respectively) were obtained in humid continental climate at the lowest studied mean water temperature (8-11 degrees C). Despite the low mean UV irradiance (-19 Wh/m(2)), 4-log disinfection of coliforms and enterococci were also reached fast in these conditions (1 h 27 min and 3 h 18 min, respectively). Overall, the doses required for disinfection increased as the water temperatures and UV intensities of the experiments rose. Disinfection of 4-logs (> 99.99%) of both bacteria was reached in all SODIS experiments within 6 h, suggesting SODIS could be a sufficient household water treatment method also in colder climates, unlike previously thought. The effects of different water temperatures on bacterial inactivation were also tested in the absence of sunlight. Together the obtained results indicate that while water temperatures below or close to the optima of coliforms and enterococci (similar to 10 degrees C) alone do not cause inactivation, these temperatures may enhance SODIS performance. This phenomenon is attributed to slower bacterial metabolism and hence slower photorepair induced by the low water temperature.es_ES
dc.formatapplication/pdfes_ES
dc.language.isoenges_ES
dc.publisherELSEVIERes_ES
dc.rightsAtribución 4.0 Internacional*
dc.rights.urihttp://creativecommons.org/licenses/by/4.0/*
dc.sourceScience of the Total Environment, Vol. 827es_ES
dc.subjectSODISes_ES
dc.subjectHousehold water treatment and safe storagees_ES
dc.subject(HWTS)es_ES
dc.subjectLow temperature disinfectiones_ES
dc.subjectFrugal technologieses_ES
dc.subjectEmergency wateres_ES
dc.titleSolar disinfection - An appropriate water treatment method to inactivate faecal bacteria in cold climateses_ES
dc.typejournal articlees_ES
dc.rights.accessRightsopen accesses_ES
dc.identifier.doi10.1016/j.scitotenv.2022.154086


Files in this item

This item appears in the following Collection(s)

Show simple item record

Atribución 4.0 Internacional
This work is under a Creative Commons License Atribución 4.0 Internacional